the alternator
led flash 6
times
alternator
and solar
panel LEDS ARE
ON
CONTINUOUSLY
1.
detected voltage
drop on the
alternator
2. alternator
insufficient power
3. power component
overheating
4. power loss on the
cables
external temperature
detected under -2°C
cables must have 10
section.
check the connections on
terminals 1,2,3 and 6.
connect the cable attached
to terminal 1 directly to the
negative pole of the engine
battery (or services), the
cable attached to terminal 2
directly to the negative pole
of the service battery (or
motor), the cable relative to
terminal 3 to the positive
pole of the engine battery,
or positive pole of the
alternator, the cable
relative to terminal 6 to the
positive pole of the service
battery.
in case of overheating of the
power components of the
electronic board, the system
automatically reduces the
current supplied for
charging, until the alarm
returns.
it's a security system in case
of charging curve 3 or 4
were selected.
the led turns of when
temperature rises above 0°c.