installation
Power Service Gold version integrates a 230VAC battery
charger, therefore other pre-existing chargers, both external
or integrated into the control unit must not to be used.
1. Set the power switch to 0.
2. Connect the negative pole of the STARTer BATTERY to
powerservice
3. Connect the fuse holder to the positive pole of the STARTer
BATTERY.
4. Connect the other end of the fuse holder to Pin N°3 of the
powerservice.
5. Insert a 70A fuse into the fuse holder.
6. Connect the negative terminal of the service battery to Pin
No. 2 of the powerservice.
7. Disconnect all the cables on the positive pole of the service
battery and connect them to pin N°5 of the
(Not valid for models plus 12-24 and gold 12-24)
8. Connect the service battery positive pole to Pin N°6 of the
powerservice
9. connect the D+ OR IGNITION+ SIGNAL WIRE to the
Pin n°4.
10. only for Gold models: connect the 230VAc mains supply to the
input iec connector. link the connection after the general
system safety switch (rcd switch).

NOTe
the data connector (placed on the right of the power
connector) is for technical use. it is strictly forbidden to
connect any device in this socket, any tampering could
irreparably damage the appliance.
use cables with a cross-section of at least 10
connections between engine battery and Power Service, and
in the output towards the service battery. if the distance
between the motor battery and the device exceeds 2 meters,
it's RECOMMENDED to increase the cable section, to reduce
voltage drop and power losses.
Pin N°1.