SECTION 24J
LIVING AREA WATER SYSTEM
The information described in Maintenance Manual X-7525 under the heading
LIVING AREA WATER SYSTEM (Sec. 24J) is applicable to models covered by this
supplement with the exception of the following:
GENERAL INFORMATION
The water system in model ZE06582 (illustrated in figure 1) functions basically the
same as model ZE06581, with the exception of the component location and the
addition of a new dry bath.
WATER SYSTEM SERVICING
(ZEOb582)
GALLEY SINK FAUCET
REPAIR
The galley sink faucet can be repaired by
REMOVAL
procuring parts from a local plumbing supply
1. Turn off water pump at water pump
distributor.
switch located beside entrance door.
Open
faucet to reduce line pressure .
INSTALLATION
2. Disconnect water lines from faucet .
1 . Position faucet assembly on sink .
3. Remove faucet retaining nut and special
2. Install special washer and faucet retain-
washer from underneath sink .
ing nut from underneath sink .
4. Remove faucet from sink .
3. Connect water lines to faucet.
WATER HEATER DRAIN COCK
WATER HEATER
WATER
CHECK
VALVE
WATER TANK DRAIN VALVE
SINK
KITCHEN SINK
't T
1
\
WATER FILL
SHOWER CONTROLS
CITY WATER INLET
DRAIN COCKS
A-5407
K
Figure 1-Living Area Water System
24J-1