Ordering Information; Specifications - Omron A22LK Series Manual

Guard lock safety key selector switch
Table of Contents

Advertisement

Ordering Information

Switch
List of Models (Completely Assembled) ... Shipped as a set which includes the Operation Unit and Switch Unit. For
Key release
Appearance
position
* Lock and release type are Solenoid lock and Mechanical release.

Specifications

Certified Standards
Certification
Standards
body
UL508, CSA C22.2
UL
No.14
EN60947-5-1
TÜV SÜD
(certified direct
opening)
CQC(CCC)
GB140485
KOSHA
KS C IEC 60947-5-1
Note: Only models with NC contacts have a direct opening mechanism.
Certified Standard Ratings
TÜV (EN60947-5-1)
Item
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the Switch.
Solenoid Coil Characteristics
Item
Rated operating voltage (100% ED) 24 VDC ±10%
Current consumption
Insulation
the model with Operation Unit only, contact your OMRON
representative.
Key position of
Lock
NC contact
position *
closing
File No.
E76675
Consult your OMRON
representative for
details.
Consult your OMRON
representative for
details.
Consult your OMRON
representative for
details.
AC-15
DC-13
3A
0.27A
240V
250V
Type
24 VDC
Approx. 88mA
Class A (130°C max.)
Key
Contact Configuration
availability
1NC/1NO+1NC/1NO
Yes
1NC/1NO+1NC/1NO
Yes
1NC/1NO+1NC/1NO
No
1NC/1NO+1NC/1NO
No
Characteristics
Item
Allowable
Mechanical
operating
Electrical
frequency
Insulation resistance
Between terminals
of same polarity
Dielectric
strength
Between each
terminal and ground
Vibration resistance *1
Destruction
Shock
resistance
Malfunction *1
Mechanical
Durability
Electrical
Ambient operating temperature *2
Ambient operating humidity
Degree of protection *3
Electric shock protection class
Degree of contamination
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm
performance before application.
3. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been
used and contact reliability for smaller loads may be
reduced.
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
A22LK
Model
A22LK-2RLA-22-K01-SJ
A22LK-2RLB-22-K01-SJ
A22LK-2RLA-22-01-SJ
A22LK-2RLB-22-01-SJ
Model
A22LK
30 operations/minute max.
30 operations/minute max.
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60Hz for
1min.
6,000 VAC, 50/60Hz for
1min.
10 to 55 Hz, 1.5mm double
amplitude (within 1 ms)
2
1000m/s
2
300m/s
100,000 operations min.
100,000 operations min.
-10 to +55°C
35% to 85%RH
IP65 *3
Class II
3 (EN60947-5-1)
5