Functional Description

Functional Controls and Displays

For ease of use, all controls and displays for the F3 Compact are located on the
Handle Assembly and Main Body. Figure 9 illustrates the location of all controls.
LED On/Off and Volume
increase button
Noise Cancel and
Volume decrease button

On/Off Switch

To switch the F3 Compact on, gently pull out the On/Off Knob and rotate
clockwise. Once in the On position release the knob back to the locked position
(referto Figure 10: Switching on the detector).
When switched on, the F3 Compact completes a series of internal start-up
functions including initialisation of the microprocessor and self-tests, which check
internal power supplies, transmitter etc.
Internal diagnostics take approximately 12 seconds to complete, during which the
operator will hear a series of rising tones (known as the Start-Up Tones).
On completion of the Start-Up Tones the F3 Compact begins detecting, when
there has been no target detection for 15 seconds the F3 Compact will emit
a Heartbeat Tone, which confirms to the operator that the F3 Compact is
functioning correctly.
14 | Functional Description
Sensitivity
On/Off knob
knob
Figure 9: F3 Compact controls
Ground Balance/Audio Reset button
Earset
socket