Siemens SINAMICS S120 Manual page 143

Power units in booksize c/d-type format
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Module without fan
Installing a new fan module
1. Insert a new fan assembly into the Motor Module. The power supply for the fan is
automatically established.
2. Retighten the fan module screws.
Tightening torque: 2.2 Nm (19.5 lbf in)
3. Attach the conductors of the motor connecting cable (protective conductor, U2, V2, W2).
Tightening torque: 6 Nm (53.1 lbf in)
4. Close the terminal block cover.
Power Units in Booksize C/D-Type Format
Manual, 12/2018, 6SL3097-5AC20-0BP0
Removed fan module
Service and support for booksize C/D-type
7.2 Replacing the fan
141