Download Print this page

Installation; Operating Instructions - PAG Pulsar 9795 Instruction Manual

All-chemistry charging system

Advertisement

U5042A PAG PULSAR INSTRUCTION MANUAL
2.13 User Interface:
The LCD screen has a display area of 94mm x 18mm, which displays 2 lines of
text, with 24 characters per line.
The screen incorporates electro-luminescent backlighting with on/off control
via the front panel soft function switch. This switch also provides for the
selection of programs and interrogation of charge and discharge data.
2.14 Safety:
Designed to comply with electrical safety standard EN 60065 & UL6500.
NOTE: UK mains plugs are fitted with a 1" fuse to BS1362 rated 5A as
standard.
2.15 European Union Directives:
Complies with the following EU Directives:
◗ EMC Directive 89/336/EU.
◗ Low Voltage Directive 73/23/EU.
2.16 Operating Temperature Range:
+32ºF to +104ºF (0ºC to 40ºC).
2.17 Overall Dimensions:
Model No. 9795 and 9797:
3.2" high x 6.6" wide x 9.5" deep. (81.5mm x 168mm x 240mm approx.).
Model No. 9796
3.1" high x 5.6" wide x 9.5" deep. (78mm x 142mm x 240mm approx.).
2.18 Weight:
Model No. 9795: 2.70lbs (1.23kg approx.).
Model No: 9796: 2.35lbs (1.07kg approx.).
Model No: 9797: 2.30lbs (1.04kg approx.).
2.19 Typical Battery Charging Times:
Battery Capacity
Charge Time 2A
1Ah
30mins
2Ah
60mins
4Ah
120mins
5Ah
150mins
7Ah
See Section 4.5
10Ah
See Section 4.5
These times are approximate only, and assume the battery is fully discharged.
Charging times will be less if the battery is already partially charged.
NOTE: PAG intelligent batteries communicate with the charger, and automatically
optimise the charging output (independently of the manual selection) to enhance
performance and safety. The above charging times do not apply to these batteries.
Charge Time 3A
Charge Time 4A
20mins
15mins
45mins
30mins
90mins
60mins
105mins
75mins
150mins
105mins
See Section 4.5
150mins
5
U5042A PAG PULSAR INSTRUCTION MANUAL
SECTION 3

INSTALLATION

3.1
All PAG Pulsar chargers are fitted with a mains input socket conforming to
CEE22 (IEC socket). This is situated on the back panel. Mains supply
connection to the charger should only be made using the standard lead
supplied with this equipment.
3.2
PAG Pulsar chargers have been designed for use on AC mains supplies
worldwide, and automatically accept supplies in the range 100-139V or 140-
250V ~ autoselected. Mains supply frequency must be in the range 50-60Hz.
3.3
PAG Pulsar chargers may be operated from a vehicle 12V battery using the
PAG Vehicle Battery-Power Converter, Model No. 9774.
3.4
PAG TECHNICAL SALES AND INFORMATION:
For further information, contact PAG USA Technical Sales and Information on
818 760 8265, PAG Technical Sales and Information (London) on +44 (0)20
8543 3131 or your nearest PAG Authorised Service Centre. Alternatively, visit
the PAG website at www.pagusa.com or www.paguk.com
SECTION 4

OPERATING INSTRUCTIONS

4.1 POWERING UP
IMPORTANT: Note section 4.11, Supply Failure. The charger remembers the
status of batteries when the mains supply is disconnected. If the charger has
been previously disconnected from the supply with 'charged' batteries
connected, it is important to connect the charger to the supply BEFORE
connecting another set of batteries.
Connect the charger to a suitable supply using the standard lead. The LCD
screen will illuminate and briefly display the PAG logo and charger model
before entering normal operating mode. With no batteries connected, all
channels will indicate 'absent'.
PAG Pulsar chargers may be disconnected from the supply at any time in
complete safety and without damage to the charger or any batteries
connected.
4.2 THE SCREEN
The screen displays two lines of information. The top line indicates battery
status, and the lower line indicates battery voltage, charge loaded, and
discharge capacity. The lower line also confirms charge rate selection.
6

Advertisement

loading

This manual is also suitable for:

Pulsar 9796Pulsar 9797