Aligning The Machine To The Driven Machine And Mounting; Selecting Bolts; Horizontal Types Of Construction With Mounting Feet; Horizontal Types Of Construction With Flange - Siemens SIMOTICS XP 1MB155 Operating Instructions Manual

Low-voltage motors
Table of Contents

Advertisement

5.4.2

Aligning the machine to the driven machine and mounting

5.4.2.1

Selecting bolts

● Unless specified otherwise, use fixing screws with at least strength class 8.8 to ISO 898-1
to ensure that the machine is securely mounted and to transmit the torque-generated
forces.
● When selecting the bolts and the design of the foundation, take into account the
maximum forces occurring in the case of a fault such as short circuit or system transfers
in phase opposition, etc.
Request the foundation force values from the Service Center if required.
See also
Tightening torques for screw and bolt connections (Page 143)
5.4.2.2

Horizontal types of construction with mounting feet

1. Refer to any instructions for aligning the driven machine and those of the coupling
manufacturer.
2. Align the machines with coupling output to the driven machine in such a manner that the
center lines of the shafts are parallel with no offset. This ensures that no additional forces
affect their bearings during operation.
3. For the vertical positioning (x→0) place thin shims under the machine feet. The number of
shims should be kept as low as possible, i.e. stack as few as possible. This also prevents
the machine being subjected to any stress/distortion. If available, use the existing tapped
holes for the forcing-off bolts to somewhat raise the machine.
4. When positioning the machine, ensure that a uniform axial gap (y→0) is maintained
around the coupling.
5. Fix the machine to the foundation. The choice of fixing elements depends on the
foundation and is the plant operator's responsibility.
Note
Machine expansion
When aligning, make allowance for the thermal expansion of the machine when the
temperature increases.
5.4.2.3

Horizontal types of construction with flange

The standard flange is provided with a centering. The choice of fit for the mating flange on
the driven machine is the system manufacturer's or the plant operator's responsibility.
If the machine is not fitted with a standard flange, align the machine to suit the driven
machine.
1MB155 / 1MB555
Operating Instructions, 03/2018, A5E41926185A
Assembly
5.4 Installing the machine
59