Overview Of Enduser Parameters - Siemens ALBATROS QAA73.110 Basic Documentation

Room unit for boiler control with opentherm interface
Hide thumbs Also See for ALBATROS QAA73.110:
Table of Contents

Advertisement

Line
Function
Time of day
1
Time of day
2
Date (day, month)
3
Year
Setpoints
5
Reduced room temperature setpoint (TRRw)
6
Frost protection setpoint of room temperature
(TRF)
7*
Nominal setpoint of the d.h.w. temperature
(TBWw)
Time switch program 1 (heating circuit 1)
10
Preselecting the weekday
Switch-on time period 1
11
Switch-off time period 1
12
Switch-on time period 2
13
Switch-on time period 2
14
Switch-on time period 3
15
Switch-off time period 3
16
Time switch program 2
20*
Preselecting the weekday
Switch-on time period 1
21*
Switch-off time period 1
22*
Switch-on time period 2
23*
Switch-off time period 2
24*
Switch-on time period 3
25*
Switch-off time period 3
26*
Time switch program 3 (d.h.w.)
Preselecting the weekday
30*
Switch-on time period 1
31*
Switch-off time period 1
32*
Switch-on time period 2
33*
Switch-off time period 2
34*
Switch-on time period 3
35*
Switch-off time period 3
36*
Holidays
40
Holidays start (day.month) – – Inactive
Holidays end (day.month) – –: Inactive
41
42
Heating circuit operating level during holidays
General
45
STANDARD time switch programs for HC1 + 2
and d.h.w.
(press both buttons -/+ for 3 s)
46
Summer / winter changeover temperature
47
Language
50*
Display of fault (error code of QAA73.110 or
boiler control)
Siemens Building Technologies
HVAC Products
2.6.1

Overview of enduser parameters

* These lines are only displayed in OpenTherm Plus mode. Also, the relevant functions
must be supported by boiler control.
– – : – – =
Switching point inactive
Basic Documentation QAA73.110 Room unit
Handling
Range
0 ... 23:59
1. Jan ... 31. Dec
2000 ... 2094
TRF ... TRN
4 ... TRRw
TBWR ... TBWmax
Mo...Su, week
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
Mo...Su, week
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
Mo...Su, week
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
/ 00:00 ... 24:00
– – : – –
1. Jan ... 31. Dec
1. Jan ... 31. Dec
Frost, reduced
No, yes
8 ... 30
German, English
0 ... 255
Unit
Resolution
Factory
setting
hh:mm
1 min
dd.mm
1 day
jjjj
1 year
°C
0.5
16.0
°C
0.5
10.0
°C
1
55
week-
1 day
day
hh:mm
10 min
06:00
hh:mm
10 min
22:00
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
week-
1 day
day
hh:mm
10 min
06:00
hh:mm
10 min
22:00
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
week-
1 day
day
hh:mm
10 min
06:00
hh:mm
10 min
22:00
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
hh:mm
10 min
– – : – –
dd.mm
1 day
– – : – –
dd.mm
1 day
– – : – –
Frost
No
°C
0.5
17.0
German
1
CE1P2284en
10.07.2002
15/70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents