Introduction
RDH100RF/SET consists of a RDH100RF wireless temperature controller and a RCR100/433 receiver. The RDH100RF allows you to set the desired room temperature (setpoint) for the desired time. The unit features an ergonomic setting knob for easy temperature control.
Product Overview
![Siemens - RDH100RF/SET - Product Overview Product Overview]()
Display
| Actual room temperature in ºC |
![]() | The unit controls to the selected comfort temperature |
| Indicates when there is demand for heat |
![]() | Replace batteries |
RF TEST | Appears on the screen when the transmitter is being tested. |
Setting knob
Warmer/colder knob for selecting the temperature setpoint
Battery compartment
Two alkaline batteries type AA, 1.5 V
Commissioning before start-up
Commissioning
- Remove the black transit tabs from the alkaline batteries.
- Check to see if the battery compartment is in the correct position.
- If no batteries are inserted, fit 2 alkaline batteries type AA in the battery compartment.
![]()
Selecting the required temperature
![Siemens - RDH100RF/SET - Selecting the required temperature Selecting the required temperature]()
- Turn the setting knob counter clockwise to decrease the setpoint, or clockwise to increase the setpoint in increments of 0.5°C
- The required temperature is displayed next to the comfort temperature symbol
Changing the batteries
- Get two new batteries of type AA alkaline, 1.5 volts.
- Within one minute: pull out the battery compartment and remove the batteries, then insert new batteries and replace the battery compartment. The original set values must be checked after changing batteries!
- Make certain the old batteries are disposed of properly, in compliance with environmental requirements.
Energy saving tips without sacrificing comfort
- Never allow room temperatures to exceed 21° C.
- Air out rooms: Air out rooms for short periods with open windows and doors.
RED regulation
RDH100RF/SET
- =Operating frequency: 433.94 MHz
- =Maximum Radio-Frequency power: 3.25 dBm
![Siemens - RDH100RF/SET - Buttons Overview Buttons Overview]()
Front View Receiver and Rear View Room (Transmitter)
LED Signal Indicator
The signal is good when the LED flashes green. A flashing red LED indicates that there is no signal.
Learn Button
Press and then release to learn telegram
Press > 5 s to enter parameter mode
LED Relay Indicator
Orange LED indicates relay is on.
OVERRIDE Button
Press this button to overwrite transmitter values.
RESET
Press the LEARN & OVERRIDE button for 4 seconds to delete all transmitter addresses.
LEARN Button
Press the button to learn a transmitter address.
TEST Button
Used for testing transmission.
Configuration instructions
The transmitter RDH100RF and the receiver RCR100/433 are set to communicate (bonded) with each other at the factory. If they fail it is necessary to re-bond the units due to the loss of communication, please follow the below instructions.
- Reset receiver by simultaneously pressing the LEARN & OVERRIDE button for 4 seconds.
- Press and release the LEARN button. This sets the receiver to the learn mode.
- Press and release the LEARN button on the back of the transmitter.
- A green flashing or solid LED indicates a good signal, a red flashing or solid LED indicates no signal.
- To test transmission, press the TEST button on the transmitter, switches the relay on in the receiver regardless of temperature. The RF TEST symbol appears on the thermostat display.
- An orange LED indicates that the relay is on.
Parameter setting
Parameter setting mode
- Press LEARN on the rear for 5 seconds until "P01" appears.
- Press LEARN again and the parameter value on second line flashes and is ready for adjustment.
- Adjust the parameter using setting knob.
- Press LEARN once to confirm the setting.
- Rotate the setting knob clockwise to next parameter and repeat steps 2 to 4.
- Exit parameter setting mode by rotating the setting knob clockwise to "End" and pressing LEARN button once.
![]()
Parameters
- P01 Control behaviour: 2-position 1K / 2-position 0.5 K / PID fast / PID slow (factory-setting)
- P02 Maximum temperature range
- P03 Minimum temperature range
![]()
Disposal
![]()
The device is considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage.
- Dispose of the device through channels provided for thispurpose.
- Comply with all local and currently applicable laws andregulations.
- Dispose of empty batteries in designated collection points.
Siemens Switzerland Ltd. declares that the radio equipment type
RDH100RF/SET is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at www.siemens.com/download?A6V10223354.
![]()
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Siemens RDH100RF/SET - Thermostat Manual
Need help?
Do you have a question about the RDH100RF/SET and is the answer not in the manual?
Questions and answers