Language; Indication Of Faults - Siemens ALBATROS QAA73.110 Basic Documentation

Room unit for boiler control with opentherm interface
Hide thumbs Also See for ALBATROS QAA73.110:
Table of Contents

Advertisement

Description
Line 47
Description
Info line 2 or line 50
Effect
Own displays
Other displays
Error code list
Siemens Building Technologies
HVAC Products

3.16 Language

There is a choice of languages for the display.
1. Press the line selection buttons to select line 47.
2. Press the + / – buttons to select the required language.
Setting range
German, English ...
The assignment of other languages depends on the relevant software release. They
can be selected by pressing the + / – buttons again.

3.17 Indication of faults

The room unit indicates faults that may have occurred in the unit itself or in the system.
Faults cannot be reset. They will be cleared only when rectified.
Press the Info button to select Info line 2, or the line selection buttons to select line 50.
If a fault is indicated, the fault / status code symbol flashes. The fault can be displayed
in clear text by pressing the Info button. The fault automatically displayed is always the
fault with the highest priority (most severe fault). If other faults are present at the same
time, the next fault with the highest priority will be displayed after the present fault has
been corrected.
In the case of a room unit-specific fault or a fault of Siemens boiler control, the error
code and appropriate error text will be displayed.
Example of own fault display
In the event of a fault occurring on a boiler control system of other manufacture, the
error code delivered is preceded by #.
Example of other fault display
Error code
Display QAA73.110
0
No error
10
OutsideSens
60
Room sensor
100
TimeMaster
118
W-Press low
124
Boiler temp
131
Burn lockout
142
OpenTherm
150
BMU
153
Interlock
162
AirPressSwi
Basic Documentation QAA73.110 Room unit
Description of enduser settings
Factory setting
German
Description of error
No error
Fault outside sensor
Fault room sensor
No valid external time (yearly clock)
Water pressure too low
Alarm boiler temperature (too high)
Fault burner
Missing partner unit on LPB
General BMU fault
Boiler control interlocked
Fault air pressure switch
33/70
CE1P2284en
10.07.2002