human care SINGEL 5100 Herkules User Manual

human care SINGEL 5100 Herkules User Manual

Overhead lift

Advertisement

TM
The Singel
5100 Herkules offers you a unique possibility of lifting and moving a
patient safe and easy without straining the patient as well as the caregiver during lift-
and moving moments.
The Singel
TM
5100 Herkules is intended for lifting and transferring patients e.g. from
the bed to the wheelchair, to and from the floor, for walking, standing, for visits to
the lavatory and bath and for weighting.
"Caution!" triangles are used to warn of situations that demand extra
care and attention
Lifting and transporting a person always involves a risk. It is important to read the instructions
for both the lift and the lifting equipment. Always ensure yourself that the equipment to be
used is working together with the lift. As caregiver you are responsible for the safety of the
patient and need to be aware of the patient's ability to manage the lifting situation.
Human Care Overhead Lifts are designed to lift and lower patients strictly in an vertical plane,
never at a diagonal or angled plane. When lifting a patient, the lift should be positioned
directly above the patient. When lowering a patient, the lift should be positioned directly above
the surface onto which the patient is being lowered.
LIFTING OR LOWERING A PATIENT AT A DIAGONAL OR ANGLE CAN
RESULT IN SERIOUS INJURY TO THE PATIENT OR CAREGIVER.
If using the Singel
TM
5100 Herkules lift in a way that is not recommended by Human Care,
Human Care will not take any responsibility for injuries or other accidents that may occur. If
there are any doubts, please contact the supplier.
Human Care products are constantly being updated and refined therefore we reserve us the right to
USER'S MANUAL
Overhead lift
TM
SINGEL
Art. no: 50500
IMPORTANT!
change aspects without prior notice.
5100 Herkules

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SINGEL 5100 Herkules and is the answer not in the manual?

Questions and answers

Summary of Contents for human care SINGEL 5100 Herkules

  • Page 1 Human Care Overhead Lifts are designed to lift and lower patients strictly in an vertical plane, never at a diagonal or angled plane. When lifting a patient, the lift should be positioned directly above the patient.
  • Page 2: Table Of Contents

    Table of contents Safety instructions ...................... 2 Technical specification ....................3 Product description ....................4 Intending use ......................5 Product label ......................5 Symbols on the unit ....................5 Operations ........................ 6 Charger ........................8 Belt tensioner guard ....................9 To use the lift ......................
  • Page 3: Safety Instructions

    Safety instructions Before first use, ensure that:  the lift is assembled according to the instructions  the lift accessories are correctly and securely fastened to the lift  you have read and understood the instructions for the lift and accessories ...
  • Page 4: Technical Specification

    Technical specification Lifting capacity, max: 300 kg/650 lbs/46.2 st. Start/stop soft Dimensions: 450x180x340 mm Weight 10 kg/22 lbs/1.6 st (WxHxL) 17.7x7.1x13.4 in Batteries: 2x12V 3.2Ah Emergency lowering: electronic/manual Indicator: Type: Stand by flashing GREEN Class: Internally powered Active consistent GREEN equipment Low voltage flashing RED Remote control:...
  • Page 5: Product Description

    Product description Overhead lift Singel™ 5100 Charger Remote control UP-button (remote control) DOWN-button (remote control) Belt Leg hook Telescopic bar Hanger bar hook 10. Main switch 11. UP-button (on lift) 12. DOWN-button (on lift) 13. Emergency lowering button 14. Indicator lamp 15.
  • Page 6: Intending Use

    Intending use The hoist is designed and tested for normal Indore conditions and have been classified as an IP44 product. The climatic conditions should be as follows, an ambient temperature from 0 °C to 50 °C, relative humidity from 30 % to 80 % and air pressure from 790 hPa to 1060 hPa. Product label The product label contains information concerning the equipment.
  • Page 7: Operations

    Operations Emergency stop In case of an emergency: press the RED emergency STOP button (15) To restore, simply turn the RED button. Emergency lowering In case of an emergency situation the emergency lowering button (13) is to be pressed, a signal will sound and the lift will lower.
  • Page 8 Connecting the lift to the rail Place the lift on a suitable surface. Set the main switch (10) to ON, push the down button (5, 11) and pull out a suitable length of the belt (6) and hook it on the distance strap from above, see fig.
  • Page 9: Charger

    When the battery charge level is low, the indicator on the lift will flash a RED light. Put the charger cable in the remote control (and the charging stats. The lift can only be used with a Human Care recommended charger, article number 50880.
  • Page 10: Belt Tensioner Guard

    Belt tension guard The lift is equipped with a belt tension guard that prevents unintentional discharging of the belt. To be able to pull the belt out the lift must be loaded. This means that when the lift is lowered to a surface the belt must be pulled out at the same time as the DOWN-button is pressed.
  • Page 11: Telescopic Bar Tm

    Telescopic bar Set the Telescopic bar™ (8) in the prescribed position. Ensure that the hooks (9) are in the same position on both sides. Place the patient in the selected sling according to the sling instructions and hang the sling in the hooks (9, 7).
  • Page 12: Definitions

    Definitions is the overall height of the system The distance from the ceiling down to the Telescopic bar (depending on rail solution) A = 380-460 mm/15-18.1 in (B) is the lifting interval The difference between lifts highest and lowest position (i.e., belt length). As accessory there are distance straps to adjust the length of the belt.
  • Page 13: Troubleshooting

    Troubleshooting Description Indicator lamp Action (14) Nothing happens when the Not lit 1) Check that the main switch UP-(4, 11) or DOWN-button (10) is ON. is pressed. 2) Batteries are totally discharged. Charge the lift (1) immediately 3) The emergency stop (15) is pushed in.
  • Page 14: Inspection, Care And Maintenance

    Annual inspection The lift must be inspected at least once a year and be performed by Human Care authorized personnel. Pay particular attention to parts that show wear. Installation, service and maintenance are to be performed by Human Care authorized personnel using original spare parts.
  • Page 15: Slings And Accessories

    50348 Scale Patient scale that can be used together with all Human Care lift products. Max load 320 kg/700 Ibs 20124 Distance strap Several different lengths to adjust the belt connection height to a comfortable height.
  • Page 16 • Fabriksvägen 2, SE-245 34 Staffanstorp, Sweden • • Tel. +46(0)8 - 665 35 00 • Fax +46(0)8 - 665 35 10 • • www.humancare.se •...