List Of Uefi Events - Lenovo System x3850 X6 Installation And Service Manual

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Table 66. Finding the UEFI (POST) error code
Interface to the UEFI (POST) error code
Logged on to the IMM web interface
Viewing the DSA Preboot diagnostic program test results

List of UEFI events

This section lists all messages that can be sent from UEFI.
• D.3108002 Backup GPT corruption recovered
Explanation: Backup GPT corruption recovered
Severity
Info
User Response
Complete the following steps:
1. No user action required for this event. This is for informational purposes only.
• I.11002 A processor mismatch has been detected between one or more processors in the system.
One or More Mismatched Processors Detected
Explanation: A processor mismatch has been detected between one or more processors in the system.
One or More Mismatched Processors Detected
Severity
Error
User Response
Complete the following steps:
1. This message could occur with messages about other Processor configuration problems.
Resolve those messages first.
2. If the problem persists, ensure that matching processors are installed (i.e., matching option part
numbers, etc)
3. Verify that the Processor's are installed in the correct sockets according to the service
information for this product. If not, correct that problem.
4. Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to
this Processor error.
5. (Trained Service technician only) Replace mismatching processor. Inspect Processor socket and
replace the compute book first if socket is damaged.
• I.18005 A discrepancy has been detected in the number of cores reported by one or more
processor packages within the system. Processors have mismatched number of cores
Explanation: A discrepancy has been detected in the number of cores reported by one or more processor
packages within the system. Processors have mismatched number of cores
Severity
Error
1926
System x3850 X6 and x3950 X6 Installation and Service Guide
Action
1. Open the Events menu and click Event Log.
2. Click more next to the event message and locate the
UEFI (POST) error code.
1. Go to the Event log.
2. Scroll to the right and look in the Auxillary Data
Column to find the UEFI (POST) error code.