Adjust Purge Rod - Graco A Series Instructions - Parts Manual

Plural component, impingement mix mechanical purge spray gun
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Adjust Purge Rod

1.
Engage safety lock, page 11.
2.
Close fluid valves A and B.
B
A
14
TI3850a
U
TI3837a
3.
Connect air supply and open air valve (U).
4.
Adjust purge rod with nut driver clockwise until it
just touches CeramTip, then back off 1/8-1/4 turn.
TI3829a
Be sure to back out purge rod 1-2 turns before
changing CeramTips or Polycarballoy Mix
Modules. Readjust purge rod after replacing
CeramTips or Polycarballoy Mix Modules.
Adjust Purge Rod
1/8-1/4 Turn
TI3828a
309856A