18. Use hex nut driver to install fluid manifold (AD).
Torque fluid manifold bolt to 20-30 in-lb
(2.26-3.39 N•m). Connect air quick coupler (AC).
AD
19. Connect signal cable.
313872B
Purge Rod
1. Flush Gun, page 25.
2. Follow Pressure Relief Procedure, page 22.
3. Disconnect air quick coupler (AC). Use hex nut
AC
TI14484a
4. Disconnect signal cable.
5. Remove Front End, see page 33. Inspect purge
6. Use 3/4 in. wrench to loosen front tip. Coat purge
7. Attach Front End, see page 35.
8. Attach air quick coupler to fully extend purge rod.
9. Install fluid manifold. Torque fluid manifold bolt to
10. Connect signal cable.
driver to remove fluid manifold (AD).
AD
rod for wear or damage. Replace if necessary.
rod with TSL then replace purge rod.
Tighten front tip to 60-70 in-lb (6.78-7.91 N•m)
20-30 in-lb (2.26-3.39 N•m).
Repair
AC
TI14463a
37