How To Wire Your Ceiling Fan - Emerson PRIMA SNUGGER CF905BS01 Owner's Manual

52” ceiling fan
Table of Contents

Advertisement

4. How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
4.2
Temporarily hang the Fan Motor Assembly onto the
Ceiling Mounting Plate Hook using the Radial Slot
nearest the Circular Hole (Figure 3).
NOTE: Make all wiring connections using the wire
connectors supplied in the parts bag. Make sure
that all connections are tight, including ground, and
that no bare wire is visible at the wire connectors,
except for the supply circuit ground wire.
4.3
Connect the Green Ground Wires from the Fan Motor
Assembly and the Ceiling Mounting Plate to the Supply
Green Grounding Conductor (this may be a bare wire
or wire with green colored insulation). Securely connect
wires with 12 ga. Wire Connector (supplied) (Figure 4).
4.1
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to Wire
the Ceiling Fan.
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product.
Substitution of parts or accessories not designated
for use with this product by Emerson could result in
personal injury or property damage.
FAN MOTOR
ASSEMBLY
Figure 3
CEILING MOUNTING
PLATE GREEN
GROUND WIRE
SUPPLY GREEN
GROUNDING WIRE
WIRE
CONNECTOR
FAN MOTOR
ASSEMBLY GREEN
GROUND WIRE
Figure 4
6
WARNING
CEILING
MOUNTING PLATE
HOOK
RADIAL SLOT
HOLE
U.L. Model No.: CF905-1

Advertisement

Table of Contents
loading