Technical Data; Contents Of This Chapter; Safety Data; Safety Data Values - ABB ACS880-07 User Manual

Emergency stop, configurable stop category 0 or 1 (option +q979)
Hide thumbs Also See for ACS880-07:
Table of Contents

Advertisement

Technical data

Contents of this chapter

This chapter lists the safety data, describes the ambient conditions and gives a list of
standards related to the product.

Safety data

Safety data values

This safety data is valid for the default design of the safety circuit described in this manual.
If the final design is different from the default, ABB calculates new safety data and delivers
it separately to the customer.
The safety data calculations are based on the assumption that the emergency stop is used
once a month.
The safety pulse encoder is not included in the calculations, because it is not included in
the delivery. Only the FSE module is included in the calculations (if used).

ACS880-07/07LC/17/17LC/37/37LC drives without the FSE-31 module

Stop category
SIL /
and monitor-
SILCL
ing method
Frame sizes R6...R11
Stop cat. 0
3
Stop cat. 1,
time monitoring
Stop cat. 1,
3
ramp monitor-
ing
1)
SC
PL
PFD
PFH
(T
[1/h]
1
3
e
5.3E-8
3.0E-4
3
e
5.3E-8
3.5E-4
2)
PFD
Cat.
DC
avg
avg
=2a)
(T
=5a)
[%]
1
3.5E-4
≥90
4.7E-4
≥90
Technical data 53
9
HFT
CCF
Mis-
sion
time
[a]
3
1
80
20
3
1
80
20
3) 4)
T
1
[a]
20/5/2
20/5/2