Subfunction
Possible settings /
value range
dISP
rEAd
dISP
rEAd
Turn read
direction 180°
oFF
,
InP
SEL
tch
InP
multi funct
SYnc
PLc
input
SYnc
Int
SL
1
,
SL
2
,
SL
3
,
SL
4
,
Func
SEL
SL
5
,
Master-slave
mA
2
,
assignment
mA
3
,
mA
4
,
mA
5
,
mA
6
ZEro
OFSt
no
,
Offset
YES
calibration
FctY
dEF
no
,
Factory
YES
setting
Tip!
The maximum operating range can be achieved as follows:
rESP
SPd
- Set
GAIn
SEL
- Set
- The switching threshold can be set to minimum 32 digits,
the amplifier detects objects up to display value 0.
LV463 - 03
Factory setting
(default)
dISP
,
(same read direction as
other texts)
,
oFF
,
SL
no
no
5000μs
to
(signal range XLR).
Gn 8
to
(gain stage 8).
Explanation
rEAd
Changes the read direction of the two 7-segment displays by 180º.
Use this setting to define the function of the multi funct multifunction
input (pin 2/ws-WH).
oFF:
tch InP:
SYnc PLc:
SYnc Int:
These settings must only be made if multiplex operation (master-slave
operation) of multiple sensors is desired.
Up to six sensors can be synchronized with one another in multiplex
operation.
In this case, exactly one master and 1 ... 5 slaves are always required.
Master settings:
mA
n
(number): Defines that this unit operates as master and a total of n
Example:
1
mA
4
means: Unit is the master, a total of four sensors are connected to
one another via the multi funct multifunction input.
Slave settings:
SL
n
(number):Defines that this unit operates as a slave and has the
Example:
SL
3
means: Unit is a slave with the individual address 3.
For further information
This subfunction is used for suppressing an offset signal that can result,
e.g., from crosstalk between transmitter and receiver at the fiber optic head.
To activate this function, select YES and confirm the selection by pressing
the rocker push button. The current signal value is now set to 0.
To perform another offset calibration, the previous calibration must first be
reset. To do this, select no and confirm by pressing the rocker push button.
Now again perform the offset calibration as previously described.
Notice:
Attention!
Resets all sensor settings to factory settings.
If desired, select YES and execute by pressing the rocker push button.
Pin/cable has no function
Pin/cable can be used as teach input for line teach. For
further information
Line teach / remote teach.
Pin/ cable can be used as activation input. For further
information
Synchronous operation of multiple amplifiers.
Setting for multiplex operation of up to six fiber optic amplifi-
ers. For this purpose, all multi funct multifunction inputs
(pin 2/ws-WH) are connected to one another. The master unit
(defined with the next subfunction) generates a timing signal
that is received by the slave units (defined with the next
subfunction) via the parallel connection. In a fixed time frame,
each slave successively activates its transmitter for a brief
time and supplies a signal value. To avoid mutual interfer-
ence, the transmitter is then again deactivated.
For further information
Multiplex operation of multiple amplifiers.
sensors were wired in parallel.
Value range n = 2 ... 6.
individual address n.
Value range for address n = 1 ... 5.
Multiplex operation of multiple amplifiers.
Resolution is lost when using offset suppression!
Example: display area = 4000digits, offset value = 550digits
Remaining resolution = 3450digits.