LV463
Mounting the amplifier
Spring-mounted DIN rail
mount
The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage.
Installing the fiber optics
②
①
③
Open the transparent protective cover.
Push down the lever of the fiber optic clamp to open.
Lead the KF /KFX type fiber optics in completely as far as they will go (ca. 12mm deep) into the fiber optic intake. When doing
so, observe the transmitter/receiver assignment on the amplifier (transmitter at bottom / receiver on top).
Pull up the lever of the fiber optic clamp to close. Check if the clamp is secure by pulling lightly on the fiber optics.
Close the transparent protective cover.
Controls and indicators
Lever for fiber optic clamp
Status LED (yellow)
switching output
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
DIN rail TS 35
(35mm x 7.5mm)
(35mm x 7.5mm)
④
7-segment LED display,
7-segment LED display,
4-digit, RED, signal strength
4-digit, GREEN, switching threshold
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
DIN rail TS 35
⑤
Rocker push button
+, - and press:
- Changing the switching threshold
- Sensor adjustment
Amplifier for fiber optics
Alternatively, the amplifier can also be
mounted without a DIN rail using the
mounting accessory and M3 screws.
Slide switch switching output:
light (LO)/dark (DO) switching
Slide switch operating mode:
RUN: Normal mode
PRG: Sensor adjustment
ADJ:
Perform teach;
change switching threshold
LV463 - 03