Mounting The Amplifier; Controls And Indicators - Leuze electronic LV463 Series Manual

Amplifier for fiber optics
Table of Contents

Advertisement

LV463

Mounting the amplifier

Spring-mounted DIN rail
mount
The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage.
Installing the fiber optics
Œ
Open the transparent protective cover.

Push down the lever of the fiber optic clamp to open.
Ž
Lead the KF /KFX type fiber optics in completely as far as they will go (ca. 12mm deep) into the fiber optic intake. When doing
so, observe the transmitter/receiver assignment on the amplifier (transmitter at bottom / receiver on top).

Pull up the lever of the fiber optic clamp to close. Check if the clamp is secure by pulling lightly on the fiber optics.

Close the transparent protective cover.

Controls and indicators

Lever for fiber optic clamp
Status LED (yellow)
switching output
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
DIN rail TS 35
(35mm x 7.5mm)
(35mm x 7.5mm)
7-segment LED display,
7-segment LED display,
4-digit, RED, signal strength
4-digit, GREEN, switching threshold
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
DIN rail TS 35
Rocker push button
+, - and press:
- Changing the switching threshold
- Sensor adjustment
Amplifier for fiber optics
Alternatively, the amplifier can also be
mounted without a DIN rail using the
mounting accessory and M3 screws.
Slide switch switching output:
light (LO)/dark (DO) switching
Slide switch operating mode:
RUN: Normal mode
PRG: Sensor adjustment
ADJ:
Perform teach;
change switching threshold
LV463 - 03