Leuze electronic LV463 Series Manual page 5

Amplifier for fiber optics
Table of Contents

Advertisement

LV463
Selecting a subfunction and changing the setting
1. Rock to left or right to select the desired subfunction.
2. Press rocker push button in middle position. The currently set value is displayed statically.
3. Rock to right or left to display the selectable adjustment values - these flash slowly.
4. Accept the new value by pressing the rocker push button in the middle position.
Fast flashing indicates that the new value is accepted.
5. Automatic return to the heading for the subfunction.
6. Press again to statically display the previously selected value.
Description of the subfunctions
Subfunction
Possible settings /
value range
200
t
=
rESP
SPd
rESP
500
Select
2000
response time
5000
GAIn
SEL
Gain stage
Select
Gn 1
gain
...
Teach modes
tch
SEL
1 Pt
tch
Select teach
2 Pt
tch
mode
dYn
tch
Auto
thr
Tracking the switching threshold
Threshold
oFF
On
,
tracking
OFF
dLY
0
1
Switch-off
(off),
delay
OFF
ISho
0
1
Passing contact
(off),
OFF
On
dLY
0
1
(off),
Switch-on
delay
On
ISho
0
1
Passing contact
(off),
ON
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
Factory setting
(default)
(signal range HS)
(signal range STD)
500
(signal range LR)
μs
(signal range XLR)
Auto
Gn 8
Auto
GAIn
;
1 Pt
(static),
(static),
(dynamic)
oFF
9999
ms
0
...
(milliseconds)
9999
ms
0
...
(milliseconds)
9999
ms
0
...
(milliseconds)
9999
ms
0
...
(milliseconds)
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
Explanation
The response time is the max. time required by the switching output to
switch to the active state following a signal change at the input.
From this, the switching frequency can be calculated as follows:
μs
1
f =
2
t
rESP
Notice: A change to the response time is equivalent to a change to the
signal range.
The gain stage can be set either by manually presetting a value between
Gn 1 ... Gn 8 or automatically by selecting Auto GAIn. The left, red display
shows the current signal value.
GAIn
The gain stage should be selected so that the signal value is approximately
in the middle of the display area.
If Auto GAIn is selected, the device automatically determines the optimum
gain setting during teaching.
Presetting a suitable teach process.
To trigger the teach event, see Teaching operating mode.
1-point teach, static: during teaching, the current signal value is accepted
as the new switching threshold. Actuate the rocker push button to make fine
adjustments to the threshold.
2-point teach, static: the switching threshold is calculated at approximate-
ly midway between two signal values, e.g., teach to two different objects or
teach to the same object at two different distances from the probe. Example:
tch
signal value 1 = 100digits, signal value 2 = 400digits
 Switching threshold = 280digits. Actuate the rocker push button to + or
- to make fine adjustments to the threshold.
Dynamic teach: suitable for processes that cannot be stopped for teaching.
When the teach event is started, the sensor begins to scan the signal values.
On the left, red display, the signal values are constantly displayed. At the end
of the teach event, the switching threshold is calculated at approximately
midway between the smallest and largest signal value.
The function is only available during dynamic teaching. If the function is
switched on, the switching threshold is automatically and continuously
optimized by the sensor in such a way that maximum functional reliability is
ensured.
This can be used to compensate for, e.g., soiling or process changes.
Warning message:
thr
ALrt
: The limit of threshold tracking is reached - the sensor contin-
Error message:
thr
Err
:
Switch-off delay (OFF Delay):
Individually adjustable from 1 ... 9999ms.
Combination options
Passing contact on fall-back (OFF 1-Shot):
Individually adjustable from 1 ... 9999ms.
Combination options
Switch-on delay (ON Delay):
Individually adjustable from 1 ... 9999ms.
Combination options
Passing contact on actuation (ON 1-Shot):
Individually adjustable from 1 ... 9999ms.
Combination options
Amplifier for fiber optics
[Hz]
ues to operate. Cleaning and, if necessary, alignment of the
fiber optics recommended.
The limit of threshold tracking is exceeded - the sensor
stops operating. Cleaning and, if necessary, alignment of
the fiber optics urgently necessary.
Combining timing functions
Combining timing functions
Combining timing functions