LV463.XR
Up to
5000mm
10 - 30 V
DC
 Extra large operating ranges
 Two, large, easy-to-read displays for the
simultaneous display of the signal value
and the switching threshold
 Simple operation and easy-to-understand
menu functions for optimum configuration
 Internal multiplex operation of up to six
units
 Line teach or external transmitter activation
 Three different teach modes for fast sensor
adjustment
 One switching output and one analog
output for each
 One indicator diode for each of the two
outputs
 Connection via cable or cable with M12
connector
U L
C
US
LISTED
IEC 60947...
IEC 60947...
Accessories:
(available separately)
 Plastic fiber optics (KF, KFX)
 Glass fiber optics (GF)
 Ready-made cables (KB ...)
 Mounting device (BTU LV463)
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
Long Range amplifier with analog output for fiber optics
Dimensioned drawing
With cable
With M8 connector
Up to
1350mm
Mounting accessories
10
35
A
Clamping lever for fiber optic cable (unlock in direction of arrow)
B
Connection for fiber optics receiver
C
Connection for fiber optics transmitter
Electrical connection
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
BTU LV463
Part no. 50120869
5-pin connector
multi funct:
- OFF
- Line teach
- Activation input
- Multiplex operation
Details  Description of the subfunctions
NOTE: Open lead wires must be connected to a terminal box.
5-wire cable
LV463.XR analog - 01

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic LV463.XR Series

  • Page 1  Ready-made cables (KB …)  Mounting device (BTU LV463) NOTE: Open lead wires must be connected to a terminal box. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01...
  • Page 2: Technical Data

    LV463.XR Technical data Notes Optical data Throughbeam Scanning principle principle NOTE Operating range/scanning range Up to 5000mm Up to 1350mm Detailed specifications on the range/ Light source LED (modulated light) scanning range are enclosed in the Wavelength LV463.XR… 660nm (visible red light) data sheets of our fiber optics type LV463I.XR…...
  • Page 3: Order Guide

    LV463.XR7/2TV-150-M12 50133988 Red light, NPN switching output LV463.XR7/2TC 50133992 Red light, NPN switching output LV463.XR7/2TV 50133987 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01 info@leuze.com • www.leuze.com...
  • Page 4: Mounting The Amplifier

    LV463.XR Mounting the amplifier DIN rail TS 35 Spring-mounted DIN rail TS 35 (35mm x 7.5mm) DIN rail mount (35mm x 7.5mm) Alternatively, the amplifier can also be mounted without a DIN rail using the The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage. mounting accessory and M3 screws.
  • Page 5 This means that the amplifier can be taught via the multifunction input (remote teach) or configured (remote configuration) in the RUN operating mode as well. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01...
  • Page 6 LV463.XR PRG operating mode - sensor adjustment channel 1 (CH1) The LV463 can be adjusted to meet customer requirements with a simple menu-driven system. To do this, set the selector switch for the operating mode to position PRG. Depending on the position of the channel selector switch, settings can be made for the binary switching output (CH1) or the analog out- put (CH2).
  • Page 7 Further details on this topic  Multiplex operation of multiple amplifiers. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01 info@leuze.com • www.leuze.com...
  • Page 8 LV463.XR Subfunction Possible settings / Factory setting Explanation value range (default) These settings only need to be made if multiplex operation (master- slave operation) of multiple sensors is desired. A maximum of 6 sensors can be synchronized with one another in mul- tiplex operation.
  • Page 9: Time Functions

    Active state of the switching output Rising edge Set delay time Falling edge (0 … 9999ms) Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01 info@leuze.com • www.leuze.com...
  • Page 10 LV463.XR Combining timing functions Timing functions can only be combined to a limited extent. Impermissible combinations are suppressed from the subfunctions menu. Here is an overview of the permissible combinations (•): ISho ISho Switch-off Passing contact Switch-on Passing contact delay delay •...
  • Page 11 2048 set response time = 1000 μs; filter counter = 64: 1000μs x 64 = 64,000μs = 64ms Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01 info@leuze.com • www.leuze.com...
  • Page 12 LV463.XR Operating mode ADJ - teaching the analog output (CH2) Set the selector switch for the channel to position CH2 (analog output). Set the selector switch for the operating mode to the ADJ position. The analog range is always set with two points: ...
  • Page 13 If the teach input is not connected or if a static LOW signal is applied, the Operating mode selector switch is unlocked and all func- tions can be accessed as described. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01...
  • Page 14 LV463.XR Special function: Remote configuration In addition to the described line teach, a simple pulse-pause signal at the teach input can be used to perform a partial configuration of the device. To do this, make this setting in the submenu: ...
  • Page 15  In multiplex operation, the cycle time is based on the total number of units: cycle time = number of units • 1.5ms + 0.5ms. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR analog - 01...
  • Page 16 LV463.XR Synchronous operation of multiple amplifiers / operation with activation input If may also be necessary to query multiple light axes simultaneously (synchronously) . There are two ways to do this: Model 1: Wiring and adjustment according to section Multiplex operation of multiple amplifiers, but all slaves receive an identical address from 1 …...

Table of Contents