Leuze electronic LV463 Series Manual

Leuze electronic LV463 Series Manual

Amplifier for fiber optics

Advertisement

LV463
up to
1050mm
10 - 30 V
DC
 Two, large, easy-to-read displays for the
simultaneous display of the signal value
and the switching threshold
 Simple operation and easy-to-understand
menu functions for optimum configuration
 Internal multiplex operation of up to
six units
 Line teach or external transmitter activation
 Three different teach modes for fast sensor
adjustment
 Switch for changing between light and dark
switching
 One PNP or NPN switching output
 Indicator diode for operation and switching
output
 Connection via M8 connector, cable or
cable with M8 or M12 connector
IEC 60947...
IEC 60947...
Accessories:
(available separately)
 Plastic fiber optics (KF, KFX)
 Ready-made cables (KB ...)
 Mounting device (BTU LV463)
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
Dimensioned drawing
with cable
with M8 connector
up to
270mm
Mounting accessories
10
35
A
Clamping lever for fiber optic cable (unlock in direction of arrow)
B
Connection for fiber optics receiver
C
Connection for fiber optics transmitter
Electrical connection
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
BTU LV463
Part no. 50120869
4-pin plug
3-pin plug
NOTE: Open lead wires must be connected to a terminal box.
Amplifier for fiber optics
4-wire cable
multi funct: - OFF
- Line teach
- Activation input
- Multiplex operation
Details  Description of the subfunctions
LV463 - 03

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic LV463 Series

  • Page 1 - Multiplex operation Details  Description of the subfunctions NOTE: Open lead wires must be connected to a terminal box. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463 - 03...
  • Page 2: Specifications

    LV463 Specifications Remarks Optical data Throughbeam principle Scanning principle Notice! Operating range/scanning range up to 1050mm up to 270mm Light source LED (modulated light) Wavelength 660nm (visible red light) Detailed specifica- Timing tions on the range/scanning ≤ 500ms Delay before start-up range are enclosed in the Signal range High Speed (HS)
  • Page 3: Mounting The Amplifier

    - Changing the switching threshold PRG: Sensor adjustment - Sensor adjustment ADJ: Perform teach; change switching threshold Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463 - 03 info@leuze.com • www.leuze.com...
  • Page 4 LV463 Selector switch RUN: Normal mode - no settings possible. Operating mode ADJ: Press rocker push button: the set teach is executed. Rock to left - right: change the switching threshold, left = + and right = -. PRG: Menu-driven device setting via display and rocker push button. Selector switch Switching output light switching: Switching output...
  • Page 5 Passing contact (off), … (milliseconds) Individually adjustable from 1 … 9999ms.  Combination options Combining timing functions Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463 - 03 info@leuze.com • www.leuze.com...
  • Page 6 LV463 Subfunction Possible settings / Factory setting Explanation value range (default) dISP rEAd dISP rEAd dISP rEAd Turn read (same read direction as Changes the read direction of the two 7-segment displays by 180º. direction 180° other texts) Use this setting to define the function of the multi funct multifunction input (pin 2/ws-WH).
  • Page 7: Time Functions

    Time t active state of the switching output rising edge set delay time falling edge (0 … 9999ms) Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463 - 03 info@leuze.com • www.leuze.com...
  • Page 8 LV463 Combining timing functions Timing functions can only be combined to a limited extent. Impermissible combinations are suppressed from the subfunctions menu. Here is an overview of the permissible combinations (•): ISho ISho Switch-off Passing contact Switch-on Passing contact delay delay •...
  • Page 9 Cycle time = number of units • 1.5ms + 0.5ms. All multi funct multifunction inputs (pin 2/ws-WH) are connected in parallel Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463 - 03...
  • Page 10 LV463 Synchronous operation of multiple amplifiers / operation with activation input In some cases, one may also wish to query multiple light axes simultaneously (synchronously). Two options are available for this purpose: Variant 1: Wire and set according to section Multiplex operation of multiple amplifiers but assign all slaves an identical address between 1 and 5.

Table of Contents