Leuze electronic LV463 Series Manual page 4

Amplifier for fiber optics
Table of Contents

Advertisement

Selector switch
Operating mode
Selector switch
Switching output
Rocker push button
- Set switching threshold
- Navigation in menu
Indicator
Signal strength
Indicator
Switching threshold
Status LED (yellow)
Switching output state
RUN operating mode - normal operation
The RUN operating mode is the standard operating mode in which the sensor detects objects; it signals this
according to the set functions. If the selector switch for the operating mode is in the RUN position, no changes
can be made on the device. This setting is thus suitable for protection against unintended operation and
changes to device settings.
PRG operating mode - sensor adjustment
The LV463 can be adjusted to meet customer requirements with a simple menu-driven system.
To do this, set the selector switch for the operating mode to position PRG.
The menu consists of 13 successive subfunctions. Rock to right or left to freely navigate through the subfunctions.
GAIn
GAIn
rESP
rESP
SPd
SPd
Verstärkung
Antwortzeit
Select
auswählen
auswählen
response time
Auto
thr
Threshold
tracking
LV463 - 03
RUN:
ADJ:
PRG:
LO:
DO:
Rock +, -:
Button:
LED ON
LED OFF
SEL
SEL
tch
tch
SEL
SEL
Teachart
Select
Select
auswählen
gain
teach mode
OFF
dLY
OFF
ISho
Switch-off delay
Passing contact
OFF
Normal mode - no settings possible.
Press rocker push button: the set teach is executed.
Rock to left - right: change the switching threshold, left = + and right = -.
Menu-driven device setting via display and rocker push button.
Switching output light switching:
If throughbeam fiber optics are installed, the switching output is active when the
light path is free; if a scanning system is installed, the switching output is active
when an object is detected. The status LED illuminates when the switching output
is active.
Switching output dark switching:
The switching behavior is the inversion of the light switching setting.
The rocker push button can be rocked to the right and to the left and pressed
in the middle position.
In the ADJ operating mode, the switching threshold can be increased (+) or
decreased (-) by rocking. In the PRG operating mode, rock to navigate in the
menu.
Press the rocker push button in the middle position to accept a setting made in
the PRG operating mode.
In the RUN and ADJ operating modes, the display shows the current signal value.
In the PRG operating mode, information on menu navigation appears on the
display.
In the RUN and ADJ operating modes, the display shows the currently set
switching threshold. In the PRG operating mode, information on menu navigation
appears on the display.
Switching output active.
Switching output inactive.
Func
Master-slave
assignment
On
dLY
On
ISho
Start-up delay
Passing contact
ON
SEL
ZEro
OFSt
FctY
Offset
Factory setting
calibration
dISP
rEAd
InP
SEL
Turn
multi funct
read direction
input
LV463
dEF
2014/11