Leuze electronic LV463.XR Series Manual
Leuze electronic LV463.XR Series Manual

Leuze electronic LV463.XR Series Manual

Long range amplifier with 2 switching outputs for fiber optics
Hide thumbs Also See for LV463.XR Series:

Advertisement

Quick Links

LV463.XR
Up to
5000mm
10 - 30 V
DC
 Extra large operating ranges
 Two, large, easy-to-read displays for the
simultaneous display of the signal value
and the switching threshold
 Simple operation and easy-to-understand
menu functions for optimum configuration
 Internal multiplex operation of up to six
units
 Line teach or external transmitter activation
 Three different teach modes for fast sensor
adjustment
 2 switching outputs (PNP or NPN)
 One indicator diode for each of the two
outputs
 Connection via cable or cable with M12
connector
IEC 60947...
IEC 60947...
Accessories:
(available separately)
 Plastic fiber optics (KF, KFX)
 Glass fiber optics (GF)
 Ready-made cables (KD ...)
 Mounting device (BTU LV463)
Leuze electronic GmbH + Co. KG
info@leuze.com • www.leuze.com
Long Range amplifier with 2 switching outputs for fiber optics
Dimensioned drawing
With cable
With M8 connector
Up to
1350mm
Mounting accessories
10
35
A
Clamping lever for fiber optic cable (unlock in direction of arrow)
B
Connection for fiber optics receiver
C
Connection for fiber optics transmitter
Electrical connection
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
BTU LV463
Part no. 50120869
5-pin connector
multi funct:
- OFF
- Line teach
- Activation input
- Multiplex operation
Details  Description of the subfunctions
NOTE: Open lead wires must be connected to a terminal box.
5-wire cable
LV463.XR 2SWO - 02

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic LV463.XR Series

  • Page 1  Ready-made cables (KD …)  Mounting device (BTU LV463) NOTE: Open lead wires must be connected to a terminal box. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02...
  • Page 2: Technical Data

    LV463.XR Technical data Notes Optical data Throughbeam Scanning principle principle NOTE Operating range/scanning range Up to 5000mm Up to 1350mm Detailed specifications on the range/ Light source LED (modulated light) scanning range are enclosed in the Wavelength LV463.XR… 660nm (visible red light) data sheets of our fiber optics type LV463I.XR…...
  • Page 3: Order Guide

    Infrared light, 2 PNP switching outputs LV463I.XR7/4T4-150-M12 50133999 Infrared light, 2 PNP switching outputs LV463I.XR7/4T4 50133998 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02 info@leuze.com • www.leuze.com...
  • Page 4: Mounting The Amplifier

    LV463.XR Mounting the amplifier DIN rail TS 35 Spring-mounted DIN rail TS 35 (35mm x 7.5mm) DIN rail mount (35mm x 7.5mm) Alternatively, the amplifier can also be mounted without a DIN rail using the The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage. mounting accessory and M3 screws.
  • Page 5 This means that the amplifier can be taught via the multifunction input (remote teach) or configured (remote configuration) in the RUN operating mode as well. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02...
  • Page 6 LV463.XR PRG operating mode - sensor adjustment channel 1/2 (CH1/CH2) The LV463 is equipped with two switching outputs, both of which can be adjusted to meet customer requirements with a simple menu-driven system. Some parameters for channel CH1 apply for the entire device, i.e., for channel CH2 as well. Switching-output-specific parameters (switching function, sensitivity, teach mode, threshold tracking, time functions and offset) can be set for each switching output individually.
  • Page 7 180° other texts) rESP GAIn 1) The settings for functions act on both switching outputs. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02 info@leuze.com • www.leuze.com...
  • Page 8 LV463.XR Subfunction Possible settings / Factory setting Explanation value range (default) Device setting - applies the same for CH1 and CH2! With the setting, you define the function of the multi funct multifunc- tion input (pin 2/ws-WH). oFF: Pin/cable without function tch InP: Pin/cable can be used as teach input for line teach or for remote configuration.
  • Page 9: Time Functions

    Active state of the switching output Rising edge Set delay time Falling edge (0 … 9999ms) Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02 info@leuze.com • www.leuze.com...
  • Page 10 LV463.XR Combining timing functions Timing functions can only be combined to a limited extent. Impermissible combinations are suppressed from the subfunctions menu. Here is an overview of the permissible combinations (•): ISho ISho Switch-off Passing contact Switch-on Passing contact delay delay •...
  • Page 11 If the teach input is not connected or if a static LOW signal is applied, the Operating mode selector switch is unlocked and all func- tions can be accessed as described. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02...
  • Page 12 LV463.XR Special function: Remote configuration In addition to the described line teach, a simple pulse-pause signal at the teach input can be used to perform a partial configuration of the device. To do this, make this setting in the submenu: ...
  • Page 13  In multiplex operation, the cycle time is based on the total number of units: cycle time = number of units • 1.5ms + 0.5ms. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 LV463.XR 2SWO - 02...
  • Page 14 LV463.XR Synchronous operation of multiple amplifiers / operation with activation input If may also be necessary to query multiple light axes simultaneously (synchronously) . There are two ways to do this: Model 1: Wiring and adjustment according to section Multiplex operation of multiple amplifiers, but all slaves receive an identical address from 1 …...

Table of Contents