IMPORTANT INFORMATION

HEATING MODE
When the air conditioner is placed in heating mode, the indoor unit will appear to be inactive while it follows
it's preheat procedure to heat the evaporator coils. Once the coils have heated, the indoor fan will start to
run. This process usually takes 1 – 3 minutes, and is designed to ensure that cold air is not circulated.
AUTO RESTART
The air conditioner will automatically restart when electricity is restored after a power cut. If in doubt, check
the settings.
RANGE OF INTERNAL THERMOSTAT
The internal thermostat can be set at a desired temperature between 16 and 32°C. Note that whether the
desired value is achieved depends on the room size, temperature and insulation of the room.
RANGE OF HEAT PUMP FUNCTION
The heat function can be used when the external ambient temperature is above -15°C. The performance of
the heat pump will degrade with lowering external temperatures. Please note the performance will reduce
when the outdoor temperature drops below 5°C.
CAPACITY
The required cooling or heating capacity depends greatly on the location and/or use of the room where the
air conditioner is installed. Strong sunlight and the presence of people, lights or equipment creates an
additional heat load. Normal living spaces require about 350 Btu per square metre of floor surface. In strong
sunlight or if other sources of heat are present, this may be as much as 1200 Btu per sqm.
Tip: On warm days, let the air conditioner cool the room as much as possible during the night and keep the
temperature constant from night to daytime.
EMERGENCY START
In the event of a problem, the air conditioner can be operated using the emergency button under the panel
in the indoor unit. Open the front panel and press the button, the air conditioner will:
-heat if the room temperature is 20 °C or less, cool if the room temperature is 25 °C or more and for values
in between will operate in fan mode.