Further Details; Step; Advanced Adjustments; Optional Accessories - Nice MhouseKit SL1W Instructions And Warnings For Installation And Use

Sliding gate opener
Hide thumbs Also See for MhouseKit SL1W:
Table of Contents

Advertisement

Available languages

Available languages

––– STEP 10 –––

10.1 - ADVANCED ADJUSTMENTS

10.1.1 - Parameter adjustment using radio transmitter
You can use the radio transmitter to adjust certain control unit param-
eters: there are four such parameters and each of them can have four
different values (Table 9):
Parameters
Pause time
Pedestrian
opening
Motor force
"OPEN" function
(*) Original factory value
The parameters adjustment operation can be carried out by any one of
radio transmitters, as long as it is stored in mode 1, like those supplied
(see paragraph 10.4.1 "Mode 1 memorisation" ).
In the event that no transmitter stored in Mode 1, it is possible to memo-
rise one just for this phase, and delete it straight afterwards (see para-
graph 10.4.4 "Deleting a radio transmitter" ).
CAUTION! – When making adjustments using the transmitter, you must
allow the command unit time to recognise the radio command; in prac-
tice, the keys must be pressed and released slowly, with at least one
second of pressure, one second of release, and so on.
01. Press T1 and T2 together (fig. 42) on the radio transmitter for at least
5 s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 5 based on
the parameter to change.
42
Example: to adjust the pause time to 40 s.
01. Press the T1 and T2 keys and hold them down for at least
5s
02. Release T1 and T2
03. Press T1 three times
All the parameters can be adjusted as required without any contraindica-
tion; only the adjustment of the "motor force" could require special care:
• Do not use high force values to compensate for the fact that the gate
20 – English

FURTHER DETAILS

Value
10s
20s (*)
40s
60s
Gate open to 0.7m
Gate open to 1m (*)
Gate halfway open
Gate 3/4 open
Low
Medium low (*)
Medium high
High
"Open", "Stop", "Close", "Stop"
"Open", "Stop", "Close", "Open" (*)
"Open", "Close", "Open", "Close"
Open only
T1
T2
1) Pause time: time for which the gate remains open (if set to automatic
closure).
2) Pedestrian opening: pedestrian opening mode of the gate.
3) Motor force: maximum force above which the control unit detects an
obstacle, and reverses the movement.
4) "OPEN" function: sequence of movements associated to each "OPEN"
command.
TABLE 9
Action: operation to be carried out at step 3 in the adjustment phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
has anomalous friction points. Excessive force can be detrimental to the
functioning of the safety system or can damage the gate.
• If the "Motor force control" is used in support of the system for impact
force reduction, the force measurement procedure must be performed
after each adjustment, as envisaged by standard EN 12445.
• Weather conditions may affect the movement of the gate. Periodically
you may need to readjust.
10.1.2 - Checking adjustment using radio transmitter
With a radio transmitter which has been memorised in Mode 1, you can
check at any time the adjusted values for each parameter using the fol-
lowing sequence.
01. Press T1 and T2 together on the radio transmitter for at least 5s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 10 based
on the parameter to change.
04. Release the key when the flashing indicator starts flashing.
05. Count the number of flashes and, based on the number, check in
Table 6 for the corresponding value.
Parameter
Pause time
Pedestrian gate
Motor force
"OPEN" function
Example: If, after having pressed T1 and T2 for 5 s and then T1, the flash-
ing indicator will emit three flashes; the pause time has been programmed
at 40 s.

10.2 - OPTIONAL ACCESSORIES

In addition to the devices present in SL1W-SL10W, there are others avail-
able as optional accessories that can integrate with the automation system.
PR1: 24 V buffer battery; in the event of a lack of mains power supply, this
ensures at least ten full cycles.
TABLE 10
Action
Press and hold T1
Press and hold T2
Press and hold T3
Press and hold T4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhousekit sl10w

Table of Contents