2. Open the Print Head Block.
Print Head Block
3. Remove the E-Ring from the left-hand Ribbon Guide Shaft, as viewed from the Head
Lever side, and take off the Ribbon Guide Shaft.
Head Lever
Ribbon Guide Shaft
When viewed from the
lower front side
4. Disconnect the Ribbon End Sensor Harness from the Ribbon End Sensor.
Sensor Harness
NOTE: Keep the removed Ribbon
Guide Shaft for future use.
E-Ring
Ribbon End Sensor
5/15
5. Separate the Sensor PCB from the Sensor Frame.
Sensor PCB
6. Fit the Sensor PCB into the Ribbon Guide.
Sensor PCB
Ribbon Guide
7. Connect the Ribbon End Sensor Harness to the Sensor PCB.
Ribbon End Sensor Harness
Sensor Frame
Sensor PCB
Ribbon Guide
6/15