Domestic Hot Water(Dhw) - Baxi Assure Mono 5 Operation User's Manual

Heat pump air/water "inverter"
Hide thumbs Also See for Assure Mono 5:
Table of Contents

Advertisement

Use '
''、 '' ''to scroll .Press ''OK'' to select. The
following page will appear:
PRESET TEMPERATURE
PRESET
WEATHER
TEMP.
TEMP.SET
CURRENT STATE
ECO TIMER
START
END
ON/OFF
ON/OFF
Use ''ON/OFF'' to turn ON or OFF,and use
scroll.
PRESET TEMPERATURE
PRESET
WEATHER
TEMP.
TEMP.SET
CURRENT STATE
ECO TIMER
START
END
ADJUST
When the cursor is on the "START" or on the "END",you
can use '' ''
''、
INFORMATION
i
ECO MODE SET have two kinds of
curves :1.the curve of the high temperature
setting for heating,2.the curve of the low
temperature setting for heating,
It only have the curve of the high temperature
setting for heating, if the high temperature is set
for heating.
It only have the curve of the low temperature
setting for heating, if the low temperature is set
for heating.
See ''FOR SERVICEMAN''>''HEAT MODE
SETTING'' in "Installation and owner's manual
(M-thermal split indoor unit)".
The desired temperature (T1S) can't be
adjusted, when the ECO mode is ON.
You can selet the low or hige temperature
setting for heating to see the "Table 1~2".
If ECO MODE is ON and ECO TIMER is
OFF,the unit run ECO mode all the time.
If ECO MODE is ON and ECO TIMER is ON,
the unit run ECO mode according to the start
time and end time.
ECO
MODE
ON
OFF
08:00
19
:00
to
ECO
MODE
OFF
OFF
ON
08:00
19
:00
11

6.3 Domestic Hot Water(DHW)

DHW mode typically consists of the following :
1) DISINFECT
2) FAST DHW
3) TANK HEATER
4) DHW PUMP
6.3.1 Disinfect
The DISINFECT function is used to kill the legionella.In
disinfect function the tank temperature will be reached
65~70℃ forcely. The disinfect temperature is set in FOR
SERCICEMAN.See ''FOR SERCICEMAN'' > ''DHW
MODE'' > ''DISINFECT'' in "Installation and owner's
manual.
Go to ''MENU'' > ''DOMESTIC HOT WATER'' >
''DISINFECT''. Press ''OK''. The following page will
appear:
DOMESTIC HOT WATER DHW
DIS-
FAST
TANK
INFECT
DHW
HEATER
CURRENT STATE
OPERATE DAY
START
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
DOMESTIC HOT WATER DHW
DIS-
FAST
TANK
INFECT
DHW
HEATER
CURRENT STATE
OPERATE DAY
START
ON/OFF
ON/OFF
ON/OFF
ON/OFF
Use '' ''
''、
DAY'' and ''START''. If the OPERATE DAY is set
FRIDAY and the START is set 23:00,
the disinfect function will active on 23:00 Friday.
If the disinfect function is running,the following page will
appear:
.
DHW
PUMP
ON
FRI
23:00
ON/OFF
DHW
PUMP
OFF
FRI
23:00