Download Print this page

Cross Technologies 2099-2424 Instruction Manual

24v source/inserter

Advertisement

Quick Links

Instruction Manual
ALARM
DC ON
REF ON
SSPB
LNB
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment. Printed in USA.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
MENU
SSPB
+24.1V @ 1.800A
LNB
+24.2V @ 0.27A
EXECUTE
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB: www.crosstechnologies.com
E-MAIL: info@crosstechnologies.com
Model 2099-2424
MODEL 2099
SOURCE / INSERTER
EXT REF
ALARM
REMOTE
PSA
OVEN
PSB
24V Source/Inserter
February 2020, Rev. C
C
T
ROSS
ECHNOLOGIES

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2099-2424 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cross Technologies 2099-2424

  • Page 1 EXECUTE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: General

    1.1 Equipment Description The 2099-2424 10 MHz Source/Inserter is a 10 MHz, ± 0.01 ppm oven controlled crystal oscillator (OCXO) with circuitry to insert the 10 MHz signal and DC voltage on L-band lines for an LNB and SSPB. Multi- function switches select LNB and SSPB DC Power, internal or External 10 MHz, and insertion of 10 MHz on the L-band lines.
  • Page 4 1.2 Technical Characteristics TABLE 1.0 2099-2424 10 MHz Source/Inserter* TABLE 1.0 2099-2424 24V Source Inserter* 10 MHz Reference L-Band Insertion RF Input/Output Characteristics Output Characteristics (on L-Band RF) Frequency 950 to 2150 MHz & 10 MHz Level +2 dBm ±2 dB Impedance 50Ω...
  • Page 5 - W108-S Frequency Response: with option SS only ±1.0, 950-2500 MHz ±2.0, dB, 2500 MHz ±0.5 dB, 36 MHz BW *10˚C to 40˚C; Specifications subject to change without notice. © Cross Technologies, Inc. 2020 2099-2424 Manual, Rev. C Page 5 02/12/20...
  • Page 6 1.3 Monitor and Control Interface A) Remote serial interface Protocol: RS-232C/422/485, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. M&C Cable Diagram - Cross Technologies Frequency Converters and Frequency Sources Female DB-9 Male DB-9...
  • Page 7 B) Status Requests Table 1.1 lists the status requests for the 2099-2424 10 MHz Source/Inserter and briefly describes them. PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below, should be used ONLY when RS-485, (OPTION-Q), is selected. Table 1.1 2099-2424 Status Re e quests Table 1.1 2099-2424 Status Requests...
  • Page 8 Status Request continued from page 7... Table 1.1 2099-2424 Status Re e quests Table 1.1 2099-2424 Status Requests Continued... Status Requests Continu u ed... Command Syntax* Description Get all monitored statuses {aaSa} returns {Sabcdefghijklmn} where: b = DC CONV A status (0 = ok, 1 = voltage too high, 2 = voltage too low)
  • Page 9 C) Commands Table 1.2 lists the commands for the 2099-2424 10 MHz Source/Inserter and briefly describes them. After a command is sent the 2099-2424 10 MHz Source/Inserter sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where:...
  • Page 10: Installation

    2.0 Installation 2.1 Mechanical The 2099-2424 10 MHz Source/Inserter consists of one RF PCB housed in a 1 RU (1 3/4 inch high) by 12 inch deep chassis. Redundant switching, +27 VDC power supplies provides power for the assemblies if equipped with option R. Otherwise, a single switching +27 VDC power supply is used.
  • Page 11: Rear Panel Outputs

    Lights yellow when LNB 3/4A Fast Blo, voltage is present on the RF IN 1/4” Fuse (J3) center pin. FIGURE 2.1 2099-2424 Rear Panel Outputs TABLE 2.1 J1 1 9 TABLE 2.1 J19 Pinouts (DB9) Function Rx+ (RS-232C) Tx+ (RS-232C)
  • Page 12 Indicates internal reference 10 MHz insertion on oven is actively heating. LNBF RF input. NOTE: Unit will not be within specified frequency tolerance until indicator is extinguished. FIGURE 2.2 2099-2424 Front Panel Controls and Indicators 2099-2424 Manual, Rev. C Page 12 02/12/20...
  • Page 13: Operation

    2.4 Installation / Operation 2.4.1 Installing and Operating the 2099-2424 10 MHz Source/Inserter with option R. 1. PLEASE NOTE: Unit must have 1 RU Air Space above and 1 RU Air Space below. 2. Connect 100-240 ±10% VAC, 47-63 Hz to PSA and PSB connectors (Figure 2.1).
  • Page 14: Menu Settings

    Menu/Execute switch verified by the “SAVE SETTINGS?” Menu. If this sequence is not followed, none of the changes will take effect. No program changes will be evident until they are verified at the “SAVE SETTINGS?” Menu. 2099-2424 Manual, Rev. C Page 14 02/12/20...
  • Page 15 3. Vertical Switch - This switch is mounted so its movement is vertical and will toggle settings such as ON/OFF and RS232/422/485. In the case of the LEVEL setting, the vertical switch will increase or decrease the digit that is selected (within the limits of operation). 2099-2424 Manual, Rev. C Page 15 02/12/20...
  • Page 16 Save? When “R” is selected from any SAVE SETTINGS? SCROLL <> PUSH BUTTON above menu or at the end (NOTE: See next page for possible alarm conditions) Figure 2.4 Menu Display and Sequence 2099-2424 Manual, Rev. C Page 16 02/12/20...
  • Page 17 LNB v insert low LNB I Insert ok LNB v insert high STATUS 8: LNB I Insert off LNB v insert low Internal Ref low Reference ok STATUS 9: External Ref low Ref PLL Not Locked 2099-2424 Manual, Rev. C Page 17 02/12/20...
  • Page 18: Alarm Operations

    LNB I Monitor This is the current that is measured at the LNB RF loop through. The summary alarm indicator and contact closure will be set if the current is greater than 600 milliamps. 2099-2424 Manual, Rev. C Page 18 02/12/20...
  • Page 19 +/- 1 dBm. The summary alarm indicator and contact closure will be set if the internal reference cannot lock to the external reference. The external reference indicator will always be on in this mode. 2099-2424 Manual, Rev. C Page 19...
  • Page 20 4.0 Model 2099-2424 Option W65: L-Band Inserted 10 MHz Reference Power Adjustment Option W65 allows the user to independently adjust the power of the 10 MHz signal that is inserted on both (LNB and SSPB) L-band loop-throughs. NOTE: The maximum 10 MHz input power is +3 dBm when Option W65 is installed.
  • Page 21: Environmental Use Information

    G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2099-2424 Manual, Rev. C Page 21 02/12/20...
  • Page 22 ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 2099-2424 Manual, Rev. C Page 22 02/12/20...