Graco SoloTech Repair And Parts Manual

Graco SoloTech Repair And Parts Manual

Peristaltic pumps

Advertisement

Repair and Parts
SoloTech™ Peristaltic
SoloTech™
SoloTech™
Electric- - - powered
powered hose
hose pump
Electric
Electric
powered
hose
only.
only.
only.
Not approved
approved for
for use
use in in in explosive
Not
Not
approved
for
use
model
model approvals
model
approvals section.
approvals
section.
section.
Important Safety
Important
Important
Safety Instructions
Safety
Read all warnings and instructions in this manual and in your
Installation and Operation Manual. Save all instructions.
125 psi (0.9 MPa, 9 bar) Maximum Fluid
Working Pressure
See page 2 for model part numbers and
information.
Peristaltic Pumps
Pumps
Peristaltic
Pumps
pump for
for use
use in in in fluid
fluid transfer
pump
for
use
fluid
explosive atmospheres
atmospheres or or or hazardous
explosive
atmospheres
Instructions
Instructions
PROVEN QUALITY. LEADING TECHNOLOGY.
transfer and
and metering
metering applications.
transfer
and
metering
hazardous locations
locations unless
hazardous
locations
applications. For
For professional
professional use
applications.
For
professional
unless otherwise
otherwise stated
unless
otherwise
3A3367H
EN
use
use
stated in in in the
the
stated
the

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SoloTech and is the answer not in the manual?

Questions and answers

Summary of Contents for Graco SoloTech

  • Page 1 Repair and Parts 3A3367H SoloTech™ Peristaltic Peristaltic Pumps Pumps SoloTech™ SoloTech™ Peristaltic Pumps Electric- - - powered powered hose hose pump pump for for use use in in in fluid fluid transfer transfer and and metering metering applications. applications. For...
  • Page 2: Table Of Contents

    Repair..............9 Kits and Accessories........... 23 Pressure Relief Procedure......9 Technical Data ........... 24 Before You Start .......... 9 Drain the Lubricant........9 Related Manuals Manuals Related Related Manuals Manual Number Title 334859 SoloTech Peristaltic Pumps, Installation and Operation 3A3367H...
  • Page 3: Configuration Number Matrix

    Configuration Number Matrix Configuration Number Number Matrix Matrix Configuration Configuration Number Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. ST23 MAC MAC NR NR SS SS A1 A1 A1 A1 0 0 0...
  • Page 4: Warnings

    • All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations. • Wait five minutes for capacitor discharge before opening equipment. • Always use the recommended amount of genuine Graco hose lubricant to minimize build-up of static electricity. 3A3367H...
  • Page 5 Warnings WARNING WARNING WARNING PRESSURIZED PRESSURIZED PRESSURIZED EQUIPMENT EQUIPMENT EQUIPMENT HAZARD HAZARD HAZARD Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. Pressure Relief Relief Procedure Procedure when you stop spraying/dispensing and before •...
  • Page 6 Warnings WARNING WARNING WARNING MOVING MOVING MOVING PARTS PARTS HAZARD PARTS HAZARD HAZARD Moving parts can pinch, cut or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. •...
  • Page 7: Troubleshooting

    NOTE: NOTE: NOTE: • Follow the Pressure Relief Procedure, page 9 • Check all possible remedies before disassembling the pump. See the Operation Manual (334859) for troubleshooting or error information on the Graco Motor Control. Problem Problem Problem Cause Cause...
  • Page 8 Try to locate the pump as near to the fluid source as possible. Oversize the inlet piping when possible. Viscosity or specific gravity of Consult your Graco distributor for pumped fluid is too high. suitable operating conditions for your pump. Replace with a new hose and Low flow.
  • Page 9: Repair

    Repair Repair Repair Repair Pressure Relief Relief Procedure Procedure Drain the the Lubricant Lubricant Pressure Pressure Relief Procedure Drain Drain Lubricant Follow the Pressure Relief 1. Hold a pail under the drain plug (29) and unscrew Procedure whenever you see this the plug to drain the lubricant.
  • Page 10: Replace The Hose

    Repair Replace the the Hose Hose Replace Replace Hose Remove Remove Remove the the Hose Hose Hose 4. Use a wrench to remove the four nuts (35) from the hose barb assembly on one port. Pull the hose so it extends about 2–3 in. (51–76 mm) out of the pump.
  • Page 11 Repair Install Install Install the the Hose Hose Hose 1. Install a gasket (25) onto each hose barb (28) so 8. Repeat steps 3–6. that it mates with the plate (26). 9. The roller must be moved to install the hose. 2.
  • Page 12: Replace The Roller

    Repair Replace the the Roller Roller Replace Replace Roller Install Install the Install the Roller Roller Roller 1. Lubricate the eccentric shaft (9) with hose The bearings in the roller are sealed and lubricant. Slide the roller (11) onto the shaft. non-serviceable.
  • Page 13: Complete Pump Repair

    Repair Complete Pump Pump Repair Repair Complete Complete Pump Repair Disassembly Disassembly Disassembly Remove Remove the Remove the Motor Motor Output Motor Output Output Shaft Shaft Shaft Complete pump disassembly is necessary only to See Figure 4 on page 15. replace the main shaft assembly, for example in the 1.
  • Page 14 NOTICE NOTICE rotate freely and are seated against the shoulder of the shaft (6). Use only genuine Graco replacement parts. Non-standard parts will void your warranty and 2. Install the eccentric shaft key (56). may damage your equipment. 3. Coat the outer races of the shaft bearings and the inner diameter of the housing with lithium-based •...
  • Page 15 Repair Install Install Install the the Seals Seals Seals 3. Press a new seal (5) onto the pump end of the shaft (6) and a new seal (8) into the bore at the front of the pump housing (1).The lips of the 1.
  • Page 16 Repair Install Install Install the the Motor Motor Motor and and Gearbox Gearbox Gearbox Install Install the Install the Eccentric Eccentric Eccentric Shaft Shaft Shaft 1. Use an anti-seize compound to lubricate the 1. Verify that the eccentric shaft key (56) is installed. motor output shaft (6) and the keyway.
  • Page 17 Do not use glycerin hose — — — 24Y920 Half Gallon (1.89 l) lubricant if pumping strong oxidizer or acids. 24K693 24K686 Gallon (3.79 l) • Keep the pump properly filled with genuine Graco hose lubricant. 24M435 24M434 55 Gallons (208 l) 3A3367H...
  • Page 18: Parts

    Parts Parts Parts Parts 3A3367H...
  • Page 19 Parts SoloTech 10 10 Parts Parts SoloTech SoloTech Parts Part Part Part Description Description Description Part Part Part Description Description Description — — — HOUSING, pump 24Y825 CLAMP, hose, size 12 — — — 17C220 FOOT, mounting, left 25† GASKET, hose plate...
  • Page 20 Parts SoloTech 23 23 Parts Parts SoloTech SoloTech Parts Part Part Part Description Description Description Part Part Part Description Description Description — — — HOUSING 24Y826 CLAMP, hose, size 20 — — — 17C222 FOOT, mounting, left 25† GASKET, hose plate...
  • Page 21 Parts SoloTech 26 26 Parts Parts SoloTech SoloTech Parts Part Part Part Description Description Description Part Part Part Description Description Description — — — HOUSING 24Y827 CLAMP, hose, size 28 — — — 17C224 FOOT, mounting, left 25† GASKET, hose plate...
  • Page 22 Parts SoloTech 30 30 Parts Parts SoloTech SoloTech Parts Part Part Part Description Description Description Part Part Part Description Description Description — — — — — — HOUSING 25† GASKET, hose plate 17C226 FOOT, mounting, left 17B696 PLATE, hose barb...
  • Page 23: Kits And Accessories

    For systems with BLDC motors that use a NOTE: NOTE: NOTE: Also purchase Programming Cable Kit Graco Motor Control, order an extension cable from 24Y788. the first section. For systems with AC motors that use a VFD, order a field-wireable cable from the...
  • Page 24: Technical Data

    Technical Data Technical Data Data Technical Technical Data SoloTech SoloTech Peristaltic SoloTech Peristaltic Pumps Peristaltic Pumps Pumps U.S. Metric Metric Metric U.S. U.S. Maximum Fluid Working Pressure 125 psi 0.9 MPa, 9 bar Motor Horsepower/Gear Ratio See the identification tag on your gear motor.
  • Page 25 Technical Data SoloTech Peristaltic Peristaltic Pumps Pumps SoloTech SoloTech Peristaltic Pumps U.S. U.S. U.S. Metric Metric Metric Hose Hose Inner Hose Inner Inner Diameter Diameter Diameter ST10 0.39 in. 10 mm ST23 0.91 in. 23 mm 1.02 in. 26 mm...
  • Page 26 Technical Data SoloTech Peristaltic Peristaltic Pumps Pumps SoloTech SoloTech Peristaltic Pumps U.S. U.S. U.S. Metric Metric Metric Technical Specifications Specifications for for the the Graco Graco Motor Motor Control Control Technical Technical Specifications Graco Motor Control (All installations and wiring must comply with NEC and local electrical codes.)
  • Page 27 Notes Notes Notes Notes 3A3367H...
  • Page 28 Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.

This manual is also suitable for: