1.- GENERAL DESCRIPTION Dostec AC is a diaphragm or piston dosing pump with advanced control for an accurate and efficient automatic dosing. This series allows many dosing possibilities depending on the chosen head. The flow range covers from 3 to 1200 l/h (317 gph) up to pressures of 20 bar (290 psi).
The original packing is prepared so that carriage and storing of the product do not cause any damage to the product, as long as this is done far from heat sources and in dry, ventilated spaces. The packing contains: - DOSTEC-AC dosing pump - Handbook - Oil: AC1/2 250 m3...
4.1 OPERATING MODES 4.1.1. Manual mode This operation mode allows a manual regulation of dosing flow. 0 0 0 0 0 0 0240 0240 Manual MODE: Proportional 0 0 0 Analog 0 0 0 l / h l / h Batch ModBus MODE...
Page 13
PROPORTIONAL X:Y Select the number of pump strokes 0001 Change values with and confirm with 0001 Q = 025 % M = 005 pulses PROPORTIONAL X:Y Select the pump speed in % Change values with and confirm with 0001 0001 For X: 1 configuration Q must be lower than 50% M = 005 pulses PROPORTIONAL X:Y...
Page 14
Select ON if you want to do a proportional dosing with a PROPORT. volume limit. The pump will stop when it reaches the maximum Set Point 000,05 volumen to be dosed. Stop Pump Change values with and confirm with Stop Vol (1) 03,6 Set the desired maximum volume.
ANALOG INPUT Select the mA Input to second point INPUT Change values with and confirm with 00,0 mA = 16,0 mA 100 % ANALOG INPUT Select the flow in % for the second point in mA SPAN Change values with and confirm with 4 mA 000 %...
Batch mode settings BATCH MODE Start Man. Manual: press to start the pump Flow 000 % Stop Stroke BATCH MODE Start Ext.: start the pump throught remote input Flow 000 % Stop Stroke BATCH MODE Start Time Time: start the pump through a timer by introducing a frecuency Flow 000 % (00:00:01 - 23:59:59)
Page 17
BATCH MODE Time: set the runtime before stop Start Man. Flow 050 % Stop Time BATCH MODE Change values with Start Man. Flow 050 % and confirm with Stop 00 : 00 : 10 Volume 333,33 l Configuration modes view Volumen to dose 01,379 l Start :...
4.1.5 ModBus mode 0 0 0 0 0 0 0240 0 240 MODE: Manual Proportional 0 0 0 Analog 0 0 0 l / h l / h l / h Batch ModBus MODE Command Address Name Value Read 00 00 Dosing Flow Integer Read...
4.1.5.1 Remote activation LEVEL 2 4-20mA PULSE REMOTE LEVEL 1 STOP + 24 17 18 RUN (factory default) 17 18 4.1.5.2 Test priming function 4.2 CONFIGURATION 4.2.1 Pump Calibration 0 0 0 0240 CONFIGURATION PUMP CALIBRATION PUMP CALIBRATION TEST TIME 0 0 0 DOSING MODE l / h...
Page 20
PUMP CALIBRATION Change values with and confirm with TEST TIME ENT to start PUMP CALIBRATION PUMP CALIBRATION Introduce the value in the unit PROGRESS Dosed volume and confirm with 03,333 Strokes Speed P. 0415 Max.Curr. 04,5 Press to finish the calibration process PUMP CALIBRATION Dvol: dosed volume DVol...
Page 21
4.2.2.2 Low Flow The Low Flow mode (LF) allows to pause the dosing during the discharge cycle, extendind the dosing time and therefore reducing the flow up to 1%. The other modes allow to reduce the flow up to 10%. DOSING MODE Mode: Low Flow...
4.2.3 Set up 4.2.3.1 Dosing pump Technical features of the dosing pump 0 0 0 SET UP 0240 CONFIGURATION DOSING PUMP 0 0 0 PUMP CALIBRATION UNITS l / h DOSING MODE FLOWMETER SET UP LOCK CODE IN / OUT MODE MODBUS Flow of the pump...
Page 23
4.2.3.2 Units Select the units for flow, pressure and proportion 0 0 0 SET UP 0240 CONFIGURATION DOSING PUMP PUMP CALIBRATION 0 0 0 UNITS DOSING MODE l / h FLOWMETER SET UP LOCK CODE IN / OUT MODBUS MODE UNITS Change units LITERS / GALONS with Flow...
Page 24
FLOWMETER FLOWMETER Change values with FREQUENCY : FREQUENCY : HIGH and confirm with 010.77 / puls 010.77 puls / TIME Q=0 : TIME Q=0, Time without receiving pulses necessary to identify as dlow zero. 4.2.3.4 Lock code 0 0 0 SET UP 0240 CONFIGURATION...
Page 25
MODBUS ADDRESS Address: Change values with and confirm with Baudrate: 9600 Data Bits: Parity: Stop Bits: MODBUS ADDRESS Address: Change values with and confirm with Baudrate: 9600 Data Bits: Parity: Stop Bits: MODBUS ADDRESS Address: Change values with and confirm with Baudrate: 9600 Data Bits:...
Page 26
FLOW DETECTOR IN Strokes Pump Change values with and confirm with 4.2.4.3 Pulse output Configuration of the volume/pulse to monitor the pump flow 0 0 0 0240 CONFIGURATION INPUTS PRESSURE PUMP CALIBRATION 0 0 0 FLOW DETECTOR l / h DOSING MODE OUTPUTS SET UP...
4.3 ALARMS If there is an alarm, the appropiate icon will be blinking on the main screen. If the cause of the alarm stops, the icon will remain fixed on the screen. To clear the alarm icon is necessary to stop and start the pump by pressing the “ENT” key. The safety time is 5 seconds before activating any alarm.
Page 28
LEVEL 1 PRE EMPTY LEVEL 2 EMPTY Switch on the Alarm Level relay when the alarm is on Alarm Alarm Level relay and confirm with Level 2 relay Stop pump Stop pump LEVEL 1 PRE EMPTY LEVEL 2 EMPTY Stop the pump when the alarm is on Alarm Alarm and confirm with...
Page 29
LEVEL 1 PRE EMPTY DIAPHRAGM LEAKAGE Switch on the Alarm Level relay when the alarm is on Alarm Alarm Level relay and confirm with Relay out Stop pump Stop pump DIAPHRAGM LEAKAGE Stop the pump when the alarm is on Alarm and confirm with Relay out...
Page 30
Analogue input value (mA) External pulse input value (Hz) INPUTS 0/4-20mA Pressure sensor input value (BAR/PSI) Pulse Hz External pulse input value (ON-OFF) Press Bar Pulse x:y Remote activation input Remote Number of strokes per minute St/min Pulse Flow Flow detector input value Analog output value (mA) OUTPUTS 0/4-20mA...
5.- INSTALLATION 5.1.- GENERALITIES To install this pump it is advisable to choose places protected from water, away from heat sources and with air renewal. Place the pump vertically over a totally rigid surface to achieve a proper lubrication of all inner elements. Anticipate which will be the room you will need to comfortably do the basic maintenance and install / uninstall the pump.
5.4.- HYDRAULIC INSTALLATION 5.4.1- Installation examples 10 11 Avoid suctioning the undiluted particles from the bottom of the tank. 2 Filter. It is important to install a filter (150 micron) in the suction pipe. 3 Level sensor 4 Agitator 5 Make sure to collect any liquid leakage from the cylinder’s vent/drain hole in a proper container.
5.4.2.- Recomendations for the correct installation SUCTION PIPE Long suction pipe: L>2m (6.5ft) RECOMENDED PIPE SIZE Øint L < 2 m L < 5 m AC1/ 2 1000 Ø 1000 Q max (l/h) Air in suction pipe DISCHARGE PIPE Long discharge pipe: L>5m (16 ft) RECOMENDED PIPE SIZE Øint L <...
Page 36
5.5.- ACCESSORIES 5.5.1- Diaphragm leakage detector The diaphragm leakage detector is a conductivity sensor which is able to detect conductive liquids, with a minimum conductivity of 0.05mS. The pump must be provided with the specific diaphragm flange to hold the leakage detector. Ø...
Page 37
5.5.4- Pulse output isolator The pulse output isolator allows to safely connect any dispositive to an pulse output. The pulse output is a drycontact. The pulse output isolator is not necessary when this output connects with a pulse input of another Dostec AC.
Page 40
LIST OF PARTS AC3 (Piston) CODE DESCRIPTION UNITS 28054 Electric motor 1,2Kw 6P 110/190 3ph 80/100 B14 29321 Seal motor T80 Maraz 29620 Control board AC 29622 Power board 230V AC 33429 Screw M4x20 Din 912 a-2 38301 Screw M3x8 Din7985 A2 60109 Regulator knob Dostec 60110...
Page 41
71129 Ring plate for piston cylinder D160 71151 Block D50 Ac3 71184 Eccentric shaft 15 encoder Ac3 71185.1 Block lid D50 encoder 71186 Magnet for encoder base D50 71187 Eccentric shaft 10 encoder Ac3 71188 Eccentric shaft 7,5 encoder Ac3 71189 Eccentric shaft 5 encoder Ac3 71303...
Page 44
LIST OF PARTS AC3 (Diaphragm) CODE DESCRIPTION UNITS 28054 Electric motor 1,2Kw 6P 110/190 3ph 80/100 B14 29321 Seal motor T80 Maraz 60109 Regulator knob Dostec 60110 Regulator guide p1,5mm Dostec 60156 Magnet for encoder d6x2.5 60300 Oil peep hole 60301 Regulator knob plug 60304...
Page 45
71214.1-P/F Cylinder diaphragm ring plate D142 71215.1-P/F Cylinder diaphragm ring plate D163 71217 Diaphragm flange D142 71218 Diaphragm flange D163 71221 Base membrana D142 71222 Base membrana D163 71225 Diaphragm D163 71226 Diaphragm D142 71303 Wedging piece Din 6885-a (8x7x25) 71304 Screw M6x10 Din 913 8.8 71306...
Page 48
LIST OF PARTS AC1/2 (Piston) Code Description Units 28053 Motor 230Kw AC1/2 29118 Motor adapter for inverter 0,5Hp 110V 29319 Seal motor Marax T71 60108 Regulation rod 15 Dostec 60109 Regulator knob Dostec 60110 Regulator guide p1,5mm Dostec 60111 Pinion bumper Dostec 60112 Dostec guide regulator p0,9mm 60114...
Page 52
LIST OF PARTS AC1/2 (Diaphragm) Code Description Units 28053 Motor 230Kw AC1/2 29118 Motor adapter for inverter 0,5Hp 110V 29129 Advanced Control case 29131 Advanced Control lid 29132 Case seal DOSTEC AC 29202 Lexan Dostec AC 29307 Screw M4x15 Din 7991 29312 O-ring 32x2 FPM 29315...
MAINTENANCE Ensure the following points before any maintenance operation: The pump is stopped and disconnected from the electric supply. There is no pressure neither inside the head nor in the discharge pipe. It is advisable to empty the head before opening it. The staff in charge of the maintenance will use the adequate protection equipment in order to manipulate the dosed liquid.
Page 56
- Check with a voltmeter incoming INPUT VOLTAGE TOO HIGH OVERVOLTAGE voltage SHORTCIRCUIT INTERNAL SHORTCIRCUIT - Contact ITC Technical Service MOTOR PHASE FAILURE PHASE FAILURE - Check the wiring between motor and electronic card AL-2 TEMPERATURE - Check the wiring of the additional...
MN+ MN- 4-20mA PULSE ALM LEVEL Violet Black LEVEL 2 4-20mA PULSE REMOTE LEVEL 1 + 24 Yellow Blue White 230V ENCODER wiring Violet Black 12v F1 F2 S - Yellow White Blue Pulse input 4-20mA ITC flowmeter ITC controllers...
EC CONFORMITY DECLARATION I.T.C S.L.. Vallès, 26 Polígono Industrial Can Bernades-Subirà 08130 Santa Perpètua de Mogoda Declares that all models DOSTEC AC products, identified by a serial number and year of manufacture, strictly fulfill 2006/042/CE,low voltages directives D2014/35/UE, and electromagnetic compatibility directivess D2014/30/UE, as long as installation, use and maintenance are carried out following the prevailing regulation and following the instructions contained in the handbook.