PEERLESS LCC 18 Installation And Assembly Manual

Ceiling mount for lcd screens up to 29"

Advertisement

Quick Links

Installation and Assembly:
Ceiling mount for LCD screens up to 29"
Models: LCC 18, LCC 18-S, LCC 36, LCC 36-S
Patent Pending
Features:
• Comes in two adjustable height ranges (in 1" increments): 18"-30" and
36"-48"
• -5° to +20° adjustable tilt
• Screen can be mounted in standard position or face-down
• Portrait or landscape orientation
• Ceiling plate included
• Hardware included for wood or concrete installations
• Theft resistant security fasteners included
®
• VESA
75/100 mm compliant (Non-VESA adapter offered separately)
• Comes in black and silver
• 360° swivel action
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessindustries.com
This product is UL Listed. It must be
installed by a qualified professional
R
installer.
Max Load Capacity: 40 lb (18.1 kg)
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05

Advertisement

Table of Contents
loading

Summary of Contents for PEERLESS LCC 18

  • Page 1 Installation and Assembly: Ceiling mount for LCD screens up to 29" Models: LCC 18, LCC 18-S, LCC 36, LCC 36-S Patent Pending Features: • Comes in two adjustable height ranges (in 1" increments): 18"-30" and 36"-48" • -5° to +20° adjustable tilt •...
  • Page 2: Table Of Contents

    Note: Read entire instruction sheet before you start installation and assembly. WARNING • Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer service at 1-800-729-0307.
  • Page 3: Parts List

    Parts List LCC 18 LCC 18-S LCC 36 LCC 36-S Description Qty. Part # Part # Part # Part # tube assembly 055-1520 055-4520 055-1521 055-4521 ceiling plate 580-1042 580-4042 580-1042 580-4042 tilt bracket 055-1551 055-4551 055-1551 055-4551 reducer 580-1009...
  • Page 4: Installation To Wood Joist Finished Ceilings, Exposed Wood Joists, Or Wood Beam Ceilings

    Installation to Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (B) with two #14 x 2.5" (6 mm x 65 mm) wood screws (E) as shown using 3/8"...
  • Page 5: Installation To Concrete Ceilings

    Installation to Concrete Ceilings Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (B) using two concrete anchors (H) and #14 x 2.5" wood screws (E) CONCRETE as shown in Illustration A and 1, 2, and 3 (below). CEILING Tighten all fasteners.
  • Page 6: Installing Reducer

    Installing Reducer Thread reducer (D) onto tube assembly (A) until tight. Insert set screw (I) into reducer as shown in figure 2-1. Tighten screw using hex wrench (J). Note: Set screw (I) is used to jam against the threads of tube assembly to prevent any excess movement.
  • Page 7: Flush Mount Installation

    Flush Mount Installation Screw reducer (D) into ceiling plate (B) until notch in reducer is aligned with one of the four holes in ceiling plate and set screw (I) is at least partially covered by ceiling plate as shown in figure 3-1. Secure reducer with one M5 x 10 mm F-type socket pin screw (P) using security allen wrench (G) as shown in figure 3-2.
  • Page 8: Installation To Extension Column

    Installation to Extension Column Screw extension column (EXT or ADJ Series) to ceiling plate (B). Align the notch with one of the four holes in the ceiling plate and secure extension column with a M5 x 10 mm socket pin screw (P) using security allen wrench (G).
  • Page 9: Installation To Lightweight Suspended Ceiling Plate

    Installation to Lightweight Suspended Ceiling Plate Refer to instruction sheet for lightweight suspended ceiling plate (CMJ 455) for attachment of ceiling plate to ceiling. Screw extension column (EXT or ADJ Series) to retaining collar in ceiling tray. Align the notch with one of the four holes in retaining collar and secure extension column with one M5 x 10 mm socket pin screw (P) using security allen...
  • Page 10: Attaching Tilt Bracket To Lcd Screen

    Attaching Tilt Bracket to LCD Screen ® Note: This product is designed to accommodate screens with VESA compliant hole patterns. For safe mounting, please make sure that mounting screws turn at least three complete turns in the screen inserts. FOR VESA 75 MOUNTING PATTERN: 1) Choose hole pattern indicated below.
  • Page 11: Installation Of Plasma In The Vertical Position

    Installation of Screen in the Vertical Position Insert two M5 x 12 mm screws (F) into column bracket of tube assembly (A) (see figure 5-1). Leave approximately 3/16" of thread exposed (see figure 5.2). 3/16" COLUMN EXPOSED BRACKET THREAD fig. 5-1 fig.
  • Page 12: Installation Of Plasma In The Horizontal Position

    12 of 12 ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05 © 2004 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.