6.2.2.
Network Configuration Settings
1
Double-click EtherCAT under
Configurations and Setup in
the Multiview Explorer.
2
Select EtherCAT Coupler Unit
NX-ECC203 in the toolbox, and
drag and drop it directly below
the master in the EtherCAT
Configuration Edit tab page.
3
Right-click NX-ECC203 in the
Multiview Explorer, and select
Coupler Connection (USB)
then Online.
After you have confirmed the
destination of the USB
connection, click the OK button.
4
Double-click NX-ECC203 in the
Multiview Explorer to open the
NX-ECC203 edit page.
Right-click in the NX-ECC203
tab page and select Compare
and Merge with Actual Unit
Configuration from the menu.