Model descriptions

Service code
Digit 1
Digit 2
Digit 3
Digit 4
Digits 5, 6 Nominal cooling capacity
Digit 7
Digit 8
Digit 9
Digit 10
Digit 11
Digit 12
Digit 13
Digit 14
Digit 15
6
M
C
D
Model
1
2
3
M
C
D
1
2
3
M = Mini split unit
C = Cooling only
W = Heat pump
D = Concealed unit
5 = Threaded connection
07 09 10 11 12 16 18 24
Design Sequence
M = Standard ducted type (only model 09, 12, 18, 24)
N = Slim ducted type (except model 24)
Power supply type
M = 220~240V/50Hz/1PH
Electric heater
N = Without electric heater(cooling only model can only choose this option)
C = With 1.0 kW electric heater (only for MWD507 , 509, 510)
D = With 1.4 kW electric heater (only for MWD511, 512)
F = With 1.8 kW electric heater (only for MWD516, 518)
H = With 2.8 kW electric heater (only for MWD524)
Controller
A = Wired controller
B = Wired + card remote controller (standard)
Design change
A = standard
B = Option With drainage pump
Optional accessories
N = Without air return plenum, without strainer, without hot water coil
M = With rear air return plenum, without strainer, without hot water coil
A = With rear air return plenum, with strainer, without hot water coil
B = With rear air return plenum, with strainer, with single-row hot water coil
D = Without rear air return plenum, without strainer, with single-row hot water coil
F = With rear air return plenum, without strainer, with single-row hot water coil
G = With rear air return plenum, with strainer, with double-row hot water coil
J = Without air return plenum, without strainer, with double-row hot water coil
S = With rear air return plenum, without strainer, with double-row hot water coil
K = With bottom air return plenum, without strainer, without hot water coil
L = With bottom air return plenum, with strainer, without hot water coil
P = With bottom air return plenum, with strainer, with single-row hot water coil
T = With bottom air return plenum, with strainer, with double-row hot water coil
Q = With bottom air return plenum, without strainer, with single-row hot water coil
Y = With bottom air return plenum, without strainer, with double-row hot water coil
(Standard strainer is made of nylon)
Coil connection (to air outlet)
L = Left (standard)
R = Right
For future
A
Language option
A = Chinese
B = English
5
1
8
M
M
4
5
6
7
8
5
1
8
M
M
4
5
6
7
8
N
B
A
9
10
11
N
B
A
N
L
9
10
11
12
13
A
B
14
15