Riello RLAS 1000 EV Installation, Use And Maintenance Instructions page 27

Dual fuel air atomizing oil/gas burner
Table of Contents

Advertisement

4.11.2 Air atomiser unit (assisted atomisation)
The Y-Jet atomiser unit has the following features:
1
Disc
type 24-S
2
Air/steam atomiser type 24-Y
3
Capnut 24
The delivery range and pulverisation angles are given are given by
the variants that are available for the element 2)(See the diagram
Fig. 22).
Nozzle RLAS 1000-1200 (air pressure = 72.5 PSI) - 6 bores type
Installation
(Fluidics)
(Fluidics)
(Fluidics)
Oil Pressure - PSI
25
GB
3
2
1
20150446
Fig. 21
20162867
Fig. 22