⑵ Installation of top cover thread guide
The clearance between the lower side of the top cover
thread guide④ to the upper side of the spreader① is
0.5mm.
Fix the screw⑤ when the spreader is at its far right, in
order to hook the thread well onto the thread hooking
part.
⑶ Installing the top cover thread eyelet
When the needle bar is at its lowest, the clearance between
the upper side of the top cover thread guide ④ and the
lower side of the top cover thread eyelet ⑥ is 1.0mm.
Bring the needle groove of top cover thread eyelet ⑥ to
the centerline of the slots of the top cover thread guide ④.
Tighten the screw ⑦ afterwards.
※ Adjust (1), (2) and (3), depending on the type of
thread used.
⑷ Adjusting decorative thread
The lifting of decorative thread eyelet(right) ① in the
(+)Y direction reduces thread supply, and the lowering of
the eyelet in the (-)Y direction increases thread supply.
When using the elastic decorative thread like wooly
thread, loosen the fixing screw② and lower the decorative
thread eyelet(right) ① in the (-)Y direction.
In the case of wooly thread, pass it through the lower
thread hole.