13
|
Technical data
Applicable for: RXM42N, RXM50N, RXM60N, ARXM50N, ARXM60N, RXJ50N, RXA42B, RXA50B
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
·7.0· CuT
4-way valve
ON: heating
·12.7· CuT
Muffler
PED categories of equipment – High pressure switch: category IV; Compressor: category II; Other equipment: art.
4§3.
Installer reference guide
64
Heat exchanger
Heat exchanger thermistor
Capillary tube ·1·
·4.0· CuT
Capillary tube ·2·
·4.0· CuT
Capillary tube ·3·
·4.0· CuT
M
Propeller fan
·12.7· CuT
Discharge pipe thermistor
HPS
High pressure switch
Automatic reset
Compressor
·6.4· CuT
·6.4· CuT
Muffler with filter
Electronic expansion valve
Filter
·12.7· CuT
Muffler
Liquid receiver
Muffler
·6.4· CuT
Accumulator
·12.7· CuT
Gas stop valve
Refrigerant flow
Outdoor temperature
Thermistor
Cooling
Heating
Field piping
·6.4· CuT
Liquid stop valve
Field piping
·12.7· CuT
ARXM50~71+RXM42~71N2V1B(9) + RXP50~71M2V1B +
RXA42+50+RXF50+60B2V1B + RXF71A2V1B + RXJ50N2V1B +
ARXF50~71A2V1B
R32 split series
4P513661-7H – 2019.12