Technical Data; General Recommendations; Wiring Description - Mongoose TT1 Manual

Table of Contents

Advertisement

Available languages

Available languages

Model: TT1
Software Switch Table
Software Switch Function
1 1
Passive ARM/DISARM Mode
1 2
Passive Arm with Lock
1 3
Auto Rearm
1 4
Lock/Unlock With Ignition
1 5
Siren Chirp ON/OFF
2 3
Delayed Arming ON/OFF
2 4
Passive Arming Immobiliser
3 1
PIN Access 1÷9 Digit Code
Press button 3 to entry the setting; press once more to exit. The LED
will display current PIN Code with a respective number of flashes.
3 2
Erase OTHER transmitter Codes (Save code of Remote Being Used)
3 3
Return Software Switches to Default
3 4
Triggering the alarm if Passive Immobiliser remains armed
after the alarm system disarming.
Press button 3 to entry the setting; press once more to exit
LED Indication:
15 s – LED single flashes
30 s – LED double flashes
60 s – LED threefold flashes
4 6
Move to Installer Switches
Installation Manual

General recommendations

Before you get down to installation, disconnect the " " terminal of the car battery.
1. The main unit is to be installed inside the passenger compartment, away from sources of
moisture and heat.
2. The RF Base Station with antenna is to be mounted on the windscreen as high as possible
to reach maximal communication range between transceiver and vehicle.
3. The siren is installed in the engine compartment or in another location inaccessible for a
thief, with the megaphone down or sideward. The location must be away from heat sources and
protected from penetration of water. If the siren has a back up battery, access to the service
keyhole must be ensured.
4. The pin switches of the hood and trunk are mounted in locations protected from water and
inaccessible when the hood/trunk is closed.
5. The shock sensor is installed inside the passenger compartment on the car body's metal
structures, as close to the car's longitudinal axis as possible, and is fixed with screws or double
sided mounting pad.
6. All high power circuits should be fused for respective currents.
10
Default
Key#1
Key#2
LED ON
LED OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
1
Press 1÷9
Press 1÷9
to increase
to reduce
Press button 3
Press button 3
OFF
Press Button
OFF
required number of
To switch this
times:
function off press
1 time – in 15 s
button 2.
2 times – in 30 s
3 times – in 60 s
Press Button 3
User's Guide and Installation Manual.

Technical Data

Voltage
Current Consumption
RF Frequency
Working Temperature
Maximal Allowable Current via the Relay Contacts:
Immobiliser Relay
Indicators Relay
Central Door Lock Relays
Transmission Range

Wiring Description

N
Wire Destination
Wire Color
1
Siren Output
Brown
+ 2 A
Connect "+" wire of the pager.
2
Pager Output
White
3
Arm Output
Brown/White
" "300 mA when Armed. To control an extra normally closed blocking relay.
4
Negative Trunk Trigger Input
Grey
1. Trunk trigger input ( ) (While remote trunk opening in armed stage the input
Input 1
The mode operation of the Arm
2. Central Door lock control input (Connect to the master actuator output, which
Output you select with Installer's
function 2 3.
5
Trunk Release Output " " 300 mA
Blue/Black
Connect to the coil of the trunk release relay.
6
Ignition Input
Orange
Connect the Ignition line, where +12V appears at switching the ignition on and stays
while cranking.
7
Negative Door Trigger Input
Green
The input has the "Dome Light Cars" selectable option. (Installer function 2 2).
8
Negative Programmable Output
Brown/Black
1. Latch output
One of two options can be
2. NO blocking relay output
selected for this input with the
Installer Function 2 6.
9
Ground " "
Black
Connect to the car body.
10
Main Unit Power Supply
Green/Brown
Connect to +12V contact of the car battery via 5A fuse.
11
Lock Normally Closed Contact
Grey/Yellow
12
Lock Common Contact
Grey/Red
Built in Relay
13
Lock Normally Opened Contact
Red/Yellow
14
Unlock Normally Closed Contact
Blue/Yellow
15
Unlock Common Contact
Blue/Red
Built in Relay
16
Unlock Normally Opened Contact
Red/Black
17
Positive Programmable Input
Yellow
1. Positive Door Trigger Input.
The mode of the input operation is
2. Remote starter output.
set by the Installer function 2 5.
18
Indicators Output 1
Black/Green
Built in Relay Contact. Connect to the right side indicators feed wire.
19
Indicators Polarity
Red
Connect to +12V contact of the car battery via 15A fuse.
(In case of negative polarity of the Indicator control wire connect to the car body
via 15A fuse).
20
Indicators Output 2
Black/White
Built in Relay Contact. Connect to the left side indicators feed wire.
LED Output
2 pin White Connectore
Shock Senor and Optional Sensor
Two 4 pin White Connectors
Inputs
Power Immobiliser Relay
Two Side Exited
Built in normally closed relay.
Black Wires
Car Alarm System MONGOOSE TT1.
9...15V
20 mA
433,92 MHz
0
40...+85
C
30A
10A
15A
30m
Note
will be overridden until 10 seconds of trunk is closed.)
is grounded in "closed" position and stays free in "open" position.
See Central Door Lock Connection Diagrams