Nakanishi EMSF-3060K Operation Manual

Nakanishi EMSF-3060K Operation Manual

Motor spindle

Advertisement

Quick Links

EMSF- 3060K
Thank you for purchasing Motor Spindle " EMSF - 3060K ". This Motor Spindle is designed for grinding, small
diameter drilling and milling, etc. The E3000 CONTROLLER and Air Line Kit are rquired to drive this Motor Spindle.
Read this and all the associated component Operation Manuals carefully before use. Always keep this Operation
Manual in a place where a user can referred to for reference at any time.
1 . CAUTIONS FOR HANDLING AND OPERATION
■ Read these warnings and cautions carefully and only use in the manner intended.
■ These warnings and cautions are intended to avoid potential hazards that could result in personal injury to the
operator or damage to the device. These are classified as follows in accordance with the seriousness of the risk.
Class
A safety hazard could result in bodily injury or damage to the device if
WARNING
the safety instructions are not properly followed.
A hazard that could result in light or moderate bodily injury or damage
CAUTION
to the device if the safety instructions are not followed.
WARNING
This Motor Spindle is not a hand tool. It is designed to be used on CNC machines or special purpose
machines.
Do not touch the cutting tool while it is running. It is very dangerous.
Wear safety glasses, dust mask, and use a protective cover around the Spindle whenever the Spindle
is rotating.
Never connect, disconnect or touch the Power Cord Plug or Motor Cord Plug with wet hands. This
may cause an electric shock.
Never operate or handle the Motor Spindle until you have thoroughly read the Operation Manuals
and safe operation has been confirmed.
1) To prevent injuries / damages, check the Motor Spindle and cutting tool for proper installation,
before operating the Motor Spindle.
2) Before disconnecting the Motor Spindle, always turn the control power off and turn the
compressed air supply to the CONTROLLER off. Then it is safe to remove the Motor Spindle.
When installing a Motor Spindle to a fixed base, make sure the fixed base is grounded in order to
avoid the risk of an electric shock.
When installing a tool, tighten the collet chuck correctly and check again the collet chuck and chuck
nut before use. Do not over-tighten the collet chuck. This may cause damage to the spindle.
Do not use bent, broken, chipped, out of round or sub-standard tools, as this may cause them to
shatter or explode. Tools with fractures or a bent shank will cause injury to the operator. When using
a new tool, rotate it in a low speed and increase speed gradually for safety.
Do not exceed the maximum recommended allowable tool speed. For your safety, use speeds below
the maximum allowable speed.
Do not apply excessive force. This may cause tool slippage, tool damage, injury to the operator
or loss of concentricity and precision.
Motor Spindle
OPERATION MANUAL
Degree of Risk
OM-K0619E 001
1

Advertisement

Table of Contents
loading

Summary of Contents for Nakanishi EMSF-3060K

  • Page 1 Motor Spindle EMSF- 3060K OPERATION MANUAL OM-K0619E 001 Thank you for purchasing Motor Spindle " EMSF - 3060K ". This Motor Spindle is designed for grinding, small diameter drilling and milling, etc. The E3000 CONTROLLER and Air Line Kit are rquired to drive this Motor Spindle. Read this and all the associated component Operation Manuals carefully before use.
  • Page 2: Basic Package

    When opening the package, check if it includes all items listed in " Table.1 Packing List Contents ". In the event of any shortage, please contact either NAKANISHI (see the " 4. CONTACT US " section) or your local dealer.
  • Page 3: Warranty

    : 800-585-4675 Telephone No. : 847-843-7664 Fax No. : 847-843-7622 Web Address : www.nskamericacorp.com For Other Markets Company Name Business Hours : 8:00am to 17:00pm (closed Saturday, Sunday and Public Holidays) Telephone No. : +81 (0) 289-64-3520 Web Address : webmaster-ie@nsk-nakanishi.co.jp...
  • Page 4: Specifications And Dimensions

    5 . FEATURES ① The Motor Spindle housing is made from precision ground, hardened, stainless steel (SUS) with an outside diameter of 30mm. ② Excellent durability and high reliability are obtained by using a high-speed brushless motor, which eliminates the need for brush replacement and frequent maintenance. ③...
  • Page 5: Changing The Tool

    7 . CHANGING THE TOOL CAUTION Do not tighten the collet chuck without inserting a tool or dummy bur, as this will damage the collet chuck, spindle or chuck nut, causing difficulty removing the collet chuck. RECOMMENDATION Please set the cutting tools to minimize the overhang amount. 13mm is the maximum amount of overhang to maintain high accuracy and safety.
  • Page 6 9 . CONNECTION OF MOTOR CORD CAUTION ・ Before connecting to the Motor Cord to the Motor and CONTROLLER, verify the Main Power Switch in the CONTROLLER is turned OFF. If the Main Power Switch on the CONTROLLER is ON while connecting the Motor Cord, damage to the CONTROLLER is possible.
  • Page 7 Slit of Bushing Fastening Bolt Fastening Bolt Fastening Bolt Slit Split Type Holder Hexagon Socket Head Cap Screw Bushing with Slit (M4 x 16) Fig. 13 Fig. 14 11 . BREAK-IN PROCEDURE During transportation, storage or installation, the grease inside the bearings will settle. If the Spindle is suddenly run at high-speed, the grease will be ejected from the bearings, causing excessive heat that will cause bearing damage.
  • Page 8: 13 . Troubleshooting

    Inspection / Corrective Action Motor Spindle The spindles ball bearings have been damaged. Replace the ball bearings. does not rotate or (Return to NAKANISHI dealer service.) rotate smoothly. The motor has been damaged. Replace the motor. (Return to NAKANISHI dealer service.)

Table of Contents