Torque Information; Ground; General Information On Ground Connections - ABB FXE4000 Commissioning Instructions

Copa-xe/mag-xe electromagnetic flowmeter
Hide thumbs Also See for FXE4000:
Table of Contents

Advertisement

Installation
3.2.4

Torque information

Nominal size
mm
3-8
10
15
20
25
32
40
50
65
80
100
125
150
200
250
300
350
400
500
600
700
800
900
1000
3.3

Ground

3.3.1

General information on ground connections

Observe the following items when grounding the device:
Use the supplied green/yellow cable as a ground wire.
Connect the ground screw for the flowmeter primary (on flange and transmitter housing) to
the ground.
The terminal box or COPA housing must also be grounded.
For plastic pipes or pipes with insulating lining, the ground is provided by the grounding plate
or grounding electrodes.
When stray currents are present in the pipeline, install a grounding plate at the front and
back of the flowmeter primary.
For measurement-related reasons, the potentials in the ground and in the pipeline should be
identical.
An additional ground via the terminals is not required.
Note
If the flowmeter primary is installed in plastic pipeline, or in pipelines with an insulating lining,
transient current may flow through the grounding electrode in special cases. In the long term,
this may destroy the flowmeter primary, since the ground electrode will in turn degrade
electrochemically. In these special cases, the connection to the ground must be performed
using grounding plates.
12 - EN
Nominal
DN
pressure
Inch
PN
⅜"
40
⅜"
40
½"
40
¾"
40
1"
40
1¼"
40
1½"
40
2"
40
2½"
40
3"
40
4"
16
5"
16
6"
16
8"
16
10"
16
12"
16
14"
16
16"
16
20"
10
24"
10
28"
10
32"
10
36"
10
40"
10
FXE4000 (COPA-XE/MAG-XE)
Flanged units
Screws
Model DE41F,
DE43F
Nm
4 x M12
8
4 x M12
8
4 x M12
10
4 x M12
16
4 x M12
21
4 x M16
34
4 x M16
43
4 x M16
56
8 x M16
39
8 x M16
49
8 x M16
47
8 x M16
62
8 x M20
83
8 x M20
81
8 x M24
120
8 x M24
160
16 x M24
195
16 x M27
250
20 x M24
200
20 x M27
260
24 x M27
300
24 x M30
390
28 x M30
385
28 x M33
480
Variable
process
Wafer
connections for
Units
models DE21
and DE23
Nm
Nm
2,3
6,5
7
6,5
7
9
11
20
15
32
26
56
33
80
46
30
30
42
40
100
67
125
D184B133U04

Advertisement

Table of Contents
loading

Table of Contents