Graco E-Flo SP Instructions Manual page 18

Air to electric conversion kits
Table of Contents

Advertisement

Installation
14. Connect the outlet check valve (202) using the
adapter fitting (204) included in the kit. Apply thread
sealant to the threads of the check valve and the
adapter fitting prior to installation. See Figure 26.
202
F
. 26: D200 Outlet Check Valve Installation
IG
15. The pressure transducer cable from the outlet check
valve plugs into port 6 on the electric driver. See
Figure 3 on page 10 for reference.
16. Use the wire ties (203) included in the kit to secure
the pressure transducer cable to a tie rod.
17. Mount the assembled ADM mounting bracket with
four screws (214) and washers (213) as shown in
Figure 27.
18. Plug the air line hole in the top of the air controls
with the supplied plug (134) as shown in Figure 27.
234
F
. 27: D200 ADM Mounting Bracket
IG
18
204
213,214
19. Install the empty level sensor.
a. Attach the actuator bracket (227) onto the ram
air cylinder shaft as shown in Figure 28.
227
228
213,214
229
F
. 28: D200 Empty Level Sensor
IG
b. Install the level sensor bracket (228) using two
screws (214) and washers (213).
c. Attach the level sensor (229) onto the level
sensor bracket (228) as shown in Figure 28.
d. Connect one end of the harness (230) to the
level sensor. Connect the other end of the
harness to the bulk head connection labeled C3
on the ram junction box (208).
e. Use four wire ties (231) to secure the harness.
This conversion results in increased pressure to the
system. To help prevent serious injury from skin injec-
tion, all components downstream of the pump must
be rated to the new, higher maximum pressures. See
the Pressure Ratings table on page 4.
20. Verify all components downstream of the pump are
rated to the new, higher pressure. Replace any
components that are not rated to the higher
pressures.
NOTE: Converting from air to electric changes the
operation of the ram supply system. Follow the E-Flo SP
Supply Systems Installation-Parts manual and the E-Flo
SP Software Instructions for complete warnings and
instructions for the system going forward. See Related
Manuals on page 2.
C3
231
230
208
3A6931A