Technical specifications
IAR Debug Probes User Guide
22
I-jet®, I-jet Trace, and I-scope™
The adapter is automatically recognized by the IAR C-SPY® Debugger, and the adapter
powers up and the green RDY LED is turned on.
Specifications
Galvanic isolation up to 3000 V peak* (< 1 sec transients. See Important safety and
disclaimer note, page 24) with continuous working voltage operation of up to 300 V.
Compatible with I-jet
Supports JTAG, SWD, and SWO debug modes
Compatible with I-jet Trace in JTAG, SWD, and SWO modes only (ETM trace is
not supported)
Powered entirely by I-jet via pins 11 and 13 on the MIPI-20 header
The RDY LED indicates that the unit is powered and ready to use
Supports target voltages from 2.5 to 5 V
JTAG clock speed up to 32 MHz