Start up procedure for HC MM XP/HC MT XP
Start up procedure
Power
the
device HC. After
Hydrocontroller model and software version it will be
displayed:
Installation (+)
Start
(ENTER)
Press+ and then it passes automatically to:
Language
English
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
Parameter set in factory. To change only if master
broken.
Configuration
MASTER
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
Motor Power
1700 Watt
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
Max.Motor Current
0.450 Ampere
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
Garden Mode
OFF
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
If Garden Mode = ON
it passes automatically to:
Sector1 Pressure
1.50 Bar
Pressing ENTER, the value is saved in memory.
Keep
pressed
ENTER
till
"Done............."
and then it passes automatically to:
Sector2 Pressure
2.00 Bar
User Guide HC - Copyright © 2008 MAC3. All right reserved.
Via Baldanzese, 149 50041 Calenzano FI
Tel. 055 8877672 – Fax 8877068
www.mac3.it - e-mail: mac3@mac3.it
Actions
the visualization
of
Press + to start the procedure of installation.
Press ENTER to start the system without doing installation.
Press + or – to change the language
it
will
be
displayed
Press + or – to change the value:
MASTER,SLAVE1,SLAVE2
Not to be set 2 HC with the same value; only 1 HC must be
set as MASTER.
WARNING. To apply this procedure to the SLAVE disconnect
the plug RS485 before doping the start up procedure.
it
will
be
displayed
Press + or – to change the value:
Set the value of electric power written on pumps label
plus 10%.
it
will
be
displayed
Press + or – to change the value
(for MT model from 0.450 to 8.500 ampere).
(fot MM model from 0.450 to 10.000 ampere)
Insert current value as indicated on the electro-pump plate.
it
will
be
displayed
Press + or – to change the value
ON: active Garden Mode
OFF: deactive Garden mode
it
will
be
displayed
Press + or – to change the value
(from 1.00 to 7.50)
insert the value for irrigation sectors at the first pressure set
point.
it
will
be
displayed
Press + or – to change the value
(from 1.00 to 7.50)
insert the value for irrigation sectors at the second pressure
set point.