Download Print this page

Emerson Rosemount 2501 Quick Start Manual page 19

Solids level switch rotating paddle

Advertisement

October 2019
Figure 2-8: Rosemount 2501J Mounting Examples
B
C
D
A. Vertical or angled mounting, at the top of silo, for full-silo (overfill)
detection
B. Horizontal mounting, at the top of silo, for full-silo (overfill) detection
C. Horizontal mounting for demand detection
D. Angled mounting, at the bottom of silo, for empty-silo detection
E. A protective angle is recommended depending on the load
The boot-shaped vane (paddle) is recommended for horizontal mountings
because it aligns to the movement of the solids material. See
load
and
Quick Start Guide
Sensitivity
to check that the paddle meets the application limits.