5 MAKING USE OF MODULES
5.5 Ladder Program Conversion at the Replacement of S10/4α I/O
Modules
When you replace I/O modules of an S10/4α controller by using an expansion mount base, be
sure to convert the existing ladder program by performing the following procedure.
Start
Save the ladder program.
Convert the ladder
program.
Send the ladder program.
End

5.5.1 Items necessary for ladder program conversion work

No.
Item
1
Cable
2
Cable
3
Program
4
Program
Personal
5
computer
Saves the ladder program used on the S10/4α controller.
Information on how to save it is given in Subsection 5.5.2,
"Saving the ladder program."
Converts the saved ladder program to S10mini version.
Information on how to convert it is given in Subsection 5.5.3,
"Converting the ladder program."
Sends the converted ladder program to the S10mini controller.
Information on how to send it is given in Subsection 5.5.4,
"Sending the ladder program."
Model
Connects the S10/4α controller and a personal
H24-IFC3-W
computer together.
Connects the S10mini CPU mounted in an HSC-2100
S10m-IFC3-W
expansion unit and a personal computer together.
S7890-17
Is an S10/4α Ladder Chart System software product.
S7890-02
Is an S10mini Ladder Chart System software product.
Is one that runs Microsoft® Windows® 2000 or
Microsoft® Windows® XP operating system and in
which both of the above software products are
installed.
Description