EdilKamin FANTASY Installation, Use And Maintenance Manual page 43

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is required for the stove to function correctly.
FAILURE TO PERFORM REGULAR MAINTENANCE, at least on a SEASONALbasis, could lead to poor functionality.
Any problems resulting from lack of maintenance will immediately void the warranty.
NOTE: After every 800 kg, "Mainten." will appear to remind the user to clean the smoke channels, which is the user's
responsibility. This message will disappear by pressing the "TURBO" button for 5 seconds. Upon reaching 2000 kg of pel-
lets, a "Mainten.-dealer" message will appear which will not disappear because the assistance of a DEALER is required.
This message can be reset from the parameters menu.
N.B.
- Any unauthorised modi cation is forbidden
- Use spare parts recommended by the manufacturer
- The use of pirate parts results in the guarantee becoming null and void
DAILY MAINTENANCE
Operations must be performed when the stove is off, cold and unplugged from the power supply
• Cleaning must be carried out with a vacuum cleaner. (see optional extras page 47).
• The whole procedure takes up a few minutes every day.
• Open the door and remove and empty the ash pan (** - g. B).
• DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
• Remove the combustion chamber or use the spatula to scrape it and clean out any blocked holes on all sides.
• Remove the combustion chamber (1) ( g. C) and scrape with a spatula. Clean any obstructions in the apertures.
• Suction the combustion chamber holder, clean the contact edges.
• Clean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of re.
1
**
g. B
g. C
WEEKLY MAINTENANCE
• Clean the hearth (with a brush) after having removed the smoke deviators (3 - g. D/E).
• Use the swabs (* - g. E).
• Empty the pellet hopper and clean the base with the vacuum cleaner.
• When cleaning the combustion chamber, lift the smoke caps (2 - g. F) and suction the four pipes underneath (4 - g. F).
3
3
4
4
*
2
2
g. D
g. E
g. F
- 43
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

FataSirenaStory

Table of Contents