Con rm by pressing MENU and the remaining quantity
of pellets will be displayed + that being loaded (default is 15
and can be changed using the +/- keys). Should the hopper run
out of pellets, the stove will block and 'Stop/Flame' will appear
(see page 35).
Note: Every now and again remember to reset the "pellet
reserve warning" for it to function in a more reliable
manner. For any clari cation please contact the authorised
DEALER who performed the rst 1st ignition.
This provides a reference indicator. Greater precision is
obtained by regularly zeroing the system before lling it again.
Edilkamin does not accept any responsibility for differences
from what is indicated (which may be due to external factors).
Environmental temperature adjustment
this comfortable and simple adjustment feature, as standard in
this line of products, allows you to manage the stove power
based on the environmental temperature.
After activating the "Clima Comfort" function from the para-
meters menu (ask the technical assistance centre - TAC), we
can use this function to switch off the stove when it reaches the
set temperature. This function is combined with the AUTO-
MATIC stove setting. MANUAL mode operation will in any
case remain unchanged.
After the Comfort Clima function has been enabled by the
TAC, you can activate/deactivate it from the user menu. Press
the SET key, look for the "Comfort Clima" menu with the
+/- keys, select it with the SET key, set ON/OFF with the +/ -
buttons, save the desired setting and exit using the 0/1 button.
Operation details Comfort Clima ON
when set on AUTOMATIC, the stove modulates its power
by following the temperature set by the user. On reaching
environmental temperature, the stove switches off and then
switches on again independently when the temperature drops.
Temperature selection
In "Comfort Clima" mode, by pressing the +/ - buttons on the
synoptic panel or on the remote control, you can set the display
to the desired environmental temperature. So we will have the
following situations:
-At environmental temperatures below the setting, the stove
switches on independently, modulating the power automatical-
ly.
-With environmental temperature reached (+2°C) the stove
switches to stand-by. The environmental temperature is sent
from the remote control; the remote control transmitter must
be visually aligned with the receiver of the synoptic panel.
If the remote control is incorrectly positioned, it cannot send
its recorded temperature. The stove therefore independently
switches to use of its on-board temperature sensor and conti-
nues thus until the connection with the remote is restored
Temperature adjustment with external thermostat
another temperature control system is available as an alterna-
tive to the remote control. You can in fact connect the thermo-
stat serial port to your home thermostat or any (clean output
contact) easily available one.
INSTRUCTIONS FOR USE
- 40
The stove will automatically recognise the connection with the
serial port of the thermostat under the following conditions:
With environmental temperature lower than the thermostat
setting (contact closed), the stove modulates power normally to
follow the set temperature
-With environmental temperature reached by the thermostat
(contact open), the stove switches to stand-by mode.
Temperature
Con guration
provided by the
remote control
"Comfort
Clima"
ON
parameter
"SONDA IR"
ON
parameter
Connection to
NO
serial port
no connection
-
Temperature
provided by
No adjustment
external
(factory setting)
environmental
thermostat
ON
ON
OFF
ON
Yes
NO
with blue
no connection
serial cable