Voltage Selector Switch - Honda EB5000X Owner's Manual

Hide thumbs Also See for EB5000X:
Table of Contents

Advertisement

Voltage Selector Switch

Disconnect or turn OFF all appliances or tools connected to the generator before
changing the voltage selector switch position.
The generator may be damaged if the switch position is changed with loads
connected and operating.
The power available to each receptacle depends on the position of the voltage
selector switch.
Switch
Receptacle
Position
120V ONLY
120V/240V
120V ONLY POSITION
When the voltage selector switch is in the 120V ONLY position, you do not need
to spread the load over the receptacles. You must, however, make sure the load
on any receptacle does not exceed its available power shown in the table above
and the total load does not exceed the total current available.
Total Current Available:
37.5 A (EB5000X)
45.8 A (EB6500X)
EB5000X
30A at 120V
20A at 120V
20A at 120V
30A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V
-
Available Power
None
OPERATION
EB6500X
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
22.9A at 120V
20A at 120V
20A at 120V
22.9A at 240V
59