SAFETY MESSAGE TO INSTALLERS AND USERS
People's lives depend on your safe installation of our
products. It is important to read, understand and follow all
instructions shipped with the products. In addition, listed
below are some other important safety instructions and
precautions you should follow:
To properly install this light: you must have a
good understanding of automotive electrical
procedures and systems, along with proficiency
in the installation and use of safety warning
equipment.
When drilling into a vehicle structure, be sure
that both sides of the surface are clear of any-
thing that could be damaged.
In order for the light to function properly, a
good ground connection must be made. At a
minimum, it must be attached to a solid metal
body or chassis part that will provide an effec-
tive ground path as long as the light system is
to be used.
Locate light control so the VEHICLE and
CONTROL can be operated safely under all
driving conditions.
Do not attempt to activate or deactivate light
control while driving in a hazardous situation.
You should frequently inspect the light to en-
sure that it is operating properly and that it is
securely attached to the vehicle.
File these instructions in a safe place and refer
to them when maintaining and/or reinstalling
the product.
Failure to follow all safety precautions and instruc-
tions may result in property damage, serious injury, or
death to you or others.
I.
GENERAL.
The Federal SignalMaster™ Model SMC14 is an
economical, low profile, solid state, directional light control
that is designed to operate with two Federal Signal four-
lamp directional light assemblies (Model SML4-30). The
unit is reversed polarity protected to avoid damage if the
positive and negative power connections are connected
incorrectly.
This model provides three distinctive directional
signals: left arrow, right arrow, and center out. In addition,
an alternating flash pattern produces a warning signal for
use when a directional signal may not be appropriate.
When a directional signal is selected, the lamps are
INSTRUCTION SHEET
SIGNALMASTER™ MODELS SMC14 and SML4-30
FOR
individually illuminated in a sequential sweeping motion
until all eight lamps are illuminated.
II.
SPECIFICATIONS.
Input Voltage
Polarity
Operating Temperature
Range
Standby Current
+BAT Fuse
+IGN/BAT Fuse
Output Drive
Capability (Total)
Flash Rate:
Directional
Warn
Dimensions:
Height
Width
Depth
Shipping Weight
III. INSTALLATION.
These lights are intended for secondary warn-
ing only. They are not intended for use as a
primary warning system.
A. SignalMaster Light Assembly (Model SML4-30).
Install the light assembly as described in the
instructions packed with the mounting kit. Route the cable
near the eventual location of the control unit.
B. Control Unit.
When installing equipment inside air bag equipped
vehicles, the installer MUST ensure that the equip-
ment is installed ONLY in areas recommended by
the vehicle manufacturer.
Failure to observe this warning will reduce the
effectiveness of the air bag, damage the air bag, or
potentially damage or dislodge the equipment,
causing serious injury or death to you or others.
11VDC to 16VDC.
Negative ground only.
-30° C to +65° C.
Zero amperes.
25 amperes.
1 ampere.
8, 27 watt lamps.
35 patterns/min.
60 patterns/min.
1-1/2"
6-1/8"
5"
2.0 lbs
WARNING
WARNING

Advertisement

loading

Summary of Contents for Federal Signal Corporation Signalmaster SMC14

  • Page 1 2561155A REV. A 794 Printed in U.S.A. INSTRUCTION SHEET SIGNALMASTER™ MODELS SMC14 and SML4-30 SAFETY MESSAGE TO INSTALLERS AND USERS individually illuminated in a sequential sweeping motion until all eight lamps are illuminated. People’s lives depend on your safe installation of our products.
  • Page 2 See figure 1. The supplied mounting bracket C. Electrical Connections. allows the control unit to be mounted in a variety of positions. To install the control unit, proceed as follows: WARNING CAUTION Failure to observe this WARNING may result in fire, burns or blindness. Install the control unit in an adequately ventilated area.
  • Page 3 Connect the both sets of SML4 wires to the terminal block as shown in figure 2. Positions 9 and 10 are not used. Ensure that the driver and passenger wire sets are connected to the terminal block EXACTLY as shown in figure 2. D.
  • Page 4 Communication and shipments should be addressed to: In this position, the passenger side unit produces a right arrow flashing pattern, instructing traffic Service Department to move right. Federal Signal Corporation 2645 Federal Signal Drive B. WARN switch. University Park, IL 60466 1-800-433-9132 When this switch is pressed, an alternating pattern is produced.

This manual is also suitable for:

Signalmaster sml4-30