SAFETY MESSAGE TO INSTALLERS

People's lives depend on your safe installation of our products.
It is important to read, understand and follow all instructions
shipped with the products. In addition, listed below are some other
important safety instructions and precautions you should follow:
To properly install this light: you must have a good
understanding of automotive electrical procedures
and systems, along with proficiency in the installa-
tion and use of safety warning equipment.
When drilling into a vehicle structure, be sure that
both sides of the surface are clear of anything that
could be damaged.
In order for the light to function properly, a separate
ground connection must be made. If practical, it
should be connected to the fusible link at the front
fender between the negative (-) battery terminal and
chassis ground. At a minimum, it may be attached to
a solid metal body or chassis part that will provide
an effective ground path as long as the light system
is to be used.
Locate light control so the VEHICLE and CON-
TROL can be operated safely under all driving
conditions.
Do not attempt to activate or deactivate light control
while driving in a hazardous situation.
You should frequently inspect the light to ensure
that it is operating properly and that it is securely
attached to the vehicle.
File these instructions in a safe place and refer to
them when maintaining and/or reinstalling the
product.
Failure to follow all safety precautions and instructions may
result in property damage, serious injury, or death to you or
others.
I.
GENERAL.
The Federal SignalMaster™ Models SM518A-NFPA and
SM428A-NFPA are economical, low wattage, directional light
assemblies that are designed for use in a flashing mode. Lens
colors available are: amber (standard), red, blue, green, and clear.
These models provide three distinctive and prioritized
lighting patterns. The highest priority pattern is the left arrow
and right arrow directional signal. When this signal is selected,
the lamps are individually illuminated in a sequential sweeping
motion until all eight lamps are illuminated. The lower priority
pattern is the warn signal. When this signal is selected, an
alternating flash of the four outside lamps with the two inside
lamps occurs. This signal may be used when a directional signal is
not appropriate. The lowest priority pattern is the low power warn
signal. When this signal is selected, the two outside lamps on each
side of the light assembly will alternately flash.
INSTRUCTION SHEET
SIGNALMASTER™ MODELS SM428A-NFPA AND SM518A-NFPA
FOR
II.
SPECIFICATIONS.
Input Voltage
Polarity
Operating Temperature
Range
Standby Current
+BAT Fuse
Output Drive
Capability (Total)
Flash Rate:
Directional
Warn
Low Power Warn
Dimensions:
Height
Length
Depth
Cable Length
These lights are intended for secondary warning only.
They are not intended for use as a primary warning
system.
III.
INSTALLATION.
The SignalMaster's circuitry can be damaged, or
destroyed, by static discharge. To prevent ESD, observe
anti-static procedures during installation.
A.
SignalMaster Light Assembly.
Install the light assembly as described in the instruc-
tions packed with the mounting kit.
B.
Control Head.
When installing equipment inside air bag equipped
vehicles, the installer MUST ensure that the equipment
is installed ONLY in areas recommended by the vehicle
manufacturer.
Failure to observe this warning will reduce the effective-
ness of the air bag, damage the air bag, or potentially
damage or dislodge the equipment, causing serious injury
or death to you or others.
Assemble the control head as shown in figure 1. For
proper operation of the unit, the switches must be installed as
shown. To install the control head, proceed as follows:
11VDC to 16VDC.
Negative ground only.
-30° C to +65° C.
Zero amperes.
25 amperes.
8, 27 watt lamps.
35 patterns/min.
60 patterns/min.
60 patterns/min.
SM518A
SM428A
2.6"
2.6"
50.9"
42.0"
3.4"
3.4"
35'
15'

WARNING

CAUTION
WARNING
2561472A
REV. A 898
Printed in U.S.A.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIGNALMASTER SM428A-NFPA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Federal Signal Corporation SIGNALMASTER SM428A-NFPA

  • Page 1 2561472A REV. A 898 Printed in U.S.A. INSTRUCTION SHEET SIGNALMASTER™ MODELS SM428A-NFPA AND SM518A-NFPA SAFETY MESSAGE TO INSTALLERS SPECIFICATIONS. Input Voltage 11VDC to 16VDC. People’s lives depend on your safe installation of our products. It is important to read, understand and follow all instructions Polarity Negative ground only.
  • Page 2 Connect the black wire to a known good chassis CHASSIS TO CHASSIS GROUND ground. This connection must be capable of supplying 25-amperes. GROUND LEAD SWITCH BRACKET Do not connect the red wire to the positive (+) NOTE: power source terminal at this time. GOLD (NO.
  • Page 3 Connect the other end of the user-supplied 22 The directional/hazard patterns will operate as gauge wire to the control cable’s brown wire at the control head as selected by the Hazard Rocker Switch. shown in figure 2. Use an insulated connector for this connection. Hazard Rocker Switch.
  • Page 4 Service Department Remove the defective lamp by carefully pulling it Federal Signal Corporation out of the socket. Install a new lamp by aligning the pins on the 2645 Federal Signal Drive lamp base with the holes in the socket, and carefully pushing the University Park, IL 60466 lamp into the socket.

This manual is also suitable for: